中文
相关论文

相关论文: Low Dose Helical CBCT denoising by using domain fi…

200 篇论文

Cone Beam CT (CBCT) is an important imaging modality nowadays, however lower image quality of CBCT compared to more conventional Computed Tomography (CT) remains a limiting factor in CBCT applications. Deep learning reconstruction methods…

Score-based diffusion models have significantly advanced generative deep learning for image processing. Measurement conditioned models have also been applied to inverse problems such as CT reconstruction. However, the conventional approach,…

医学物理 · 物理学 2025-02-24 Matthew Tivnan , Dufan Wu , Quanzheng Li

Cone beam computed tomography (CBCT) is an important imaging technology widely used in medical scenarios, such as diagnosis and preoperative planning. Using fewer projection views to reconstruct CT, also known as sparse-view reconstruction,…

图像与视频处理 · 电气工程与系统科学 2024-06-07 Yiqun Lin , Jiewen Yang , Hualiang Wang , Xinpeng Ding , Wei Zhao , Xiaomeng Li

Low-dose computed tomography (LDCT) image reconstruction techniques can reduce patient radiation exposure while maintaining acceptable imaging quality. Deep learning is widely used in this problem, but the performance of testing data…

图像与视频处理 · 电气工程与系统科学 2024-06-04 Kecheng Chen , Jie Liu , Renjie Wan , Victor Ho-Fun Lee , Varut Vardhanabhuti , Hong Yan , Haoliang Li

In order to improve image quality of projection in industrial applications, generally, a standard method is to increase the current or exposure time, which might cause overexposure of detector units in areas of thin objects or backgrounds.…

图像与视频处理 · 电气工程与系统科学 2024-12-10 Mengyu Sun , Dimeng Xia , Shusen Zhao , Weibin Zhang , Yaobin He

Background: Dual-energy CT (DECT) and material decomposition play vital roles in quantitative medical imaging. However, the decomposition process may suffer from significant noise amplification, leading to severely degraded image…

Computed Tomography (CT) takes X-ray measurements on the subjects to reconstruct tomographic images. As X-ray is radioactive, it is desirable to control the total amount of dose of X-ray for safety concerns. Therefore, we can only select a…

医学物理 · 物理学 2021-09-15 Ziju Shen , Yufei Wang , Dufan Wu , Xu Yang , Bin Dong

Cone-Beam Computed Tomography (CBCT) is widely used for intraoperative imaging due to its rapid acquisition and low radiation dose. However, CBCT images typically suffer from artifacts and lower visual quality compared to conventional…

图像与视频处理 · 电气工程与系统科学 2025-07-09 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

医学物理 · 物理学 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang

Low-dose computed tomography (LDCT) is an important topic in the field of radiology over the past decades. LDCT reduces ionizing radiation-induced patient health risks but it also results in a low signal-to-noise ratio (SNR) and a potential…

图像与视频处理 · 电气工程与系统科学 2022-10-03 Wenjun Xia , Qing Lyu , Ge Wang

Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we…

计算机视觉与模式识别 · 计算机科学 2024-09-13 Sho Ozaki , Shizuo Kaji , Toshikazu Imae , Kanabu Nawa , Hideomi Yamashita , Keiichi Nakagawa

Cone beam computed tomography (CBCT) is a common way of diagnosing dental related diseases. Accurate segmentation of 3D tooth is of importance for the treatment. Although deep learning based methods have achieved convincing results in…

计算机视觉与模式识别 · 计算机科学 2024-07-16 Chunshi Wang , Bin Zhao , Shuxue Ding

Recently, deep learning(DL) methods have been proposed for the low-dose computed tomography(LdCT) enhancement, and obtain good trade-off between computational efficiency and image quality. Most of them need large number of pre-collected…

计算机视觉与模式识别 · 计算机科学 2018-08-09 Mingrui Geng , Yun Deng , Qian Zhao , Qi Xie , Dong Zeng , Dong Zeng , Wangmeng Zuo , Deyu Meng

With substantial public concerns on potential cancer risks and health hazards caused by the accumulated radiation exposure in medical imaging, reducing radiation dose in X-ray based medical imaging such as Computed Tomography Perfusion…

图像与视频处理 · 电气工程与系统科学 2019-10-21 Peng Liu , Ruogu Fang

Deep learning-based low-dose computed tomography reconstruction methods already achieve high performance on standard image quality metrics like peak signal-to-noise ratio and structural similarity index measure. Yet, they frequently fail to…

图像与视频处理 · 电气工程与系统科学 2025-11-11 Necati Sefercioglu , Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts,…

计算机视觉与模式识别 · 计算机科学 2025-06-17 Yuan Gao , Shaoyan Pan , Mingzhe Hu , Huiqiao Xie , Jill Remick , Chih-Wei Chang , Justin Roper , Zhen Tian , Xiaofeng Yang

Cone Beam Computed Tomography (CBCT) plays a vital role in clinical imaging. Traditional methods typically require hundreds of 2D X-ray projections to reconstruct a high-quality 3D CBCT image, leading to considerable radiation exposure.…

图像与视频处理 · 电气工程与系统科学 2024-10-08 Zhentao Liu , Yu Fang , Changjian Li , Han Wu , Yuan Liu , Dinggang Shen , Zhiming Cui

Low-dose computed tomography (LDCT) offers reduced X-ray radiation exposure but at the cost of compromised image quality, characterized by increased noise and artifacts. Recently, transformer models emerged as a promising avenue to enhance…

图像与视频处理 · 电气工程与系统科学 2023-10-20 Dayang Wang , Yongshun Xu , Shuo Han , Zhan Wu , Li Zhou , Bahareh Morovati , Hengyong Yu

LDCT has drawn major attention in the medical imaging field due to the potential health risks of CT-associated X-ray radiation to patients. Reducing the radiation dose, however, decreases the quality of the reconstructed images, which…

图像与视频处理 · 电气工程与系统科学 2022-04-19 Zhizhong Huang , Junping Zhang , Yi Zhang , Hongming Shan

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

计算机视觉与模式识别 · 计算机科学 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li