相关论文: Quantitative investigation of low-dose PET imaging…
We set out to simulate four reduced dose-levels (60%-dose, 40%-dose, 20%-dose, and 10%-dose) of standard CT imaging using Beer-Lambert's law across 49 patients infected with COVID-19. Then, three denoising filters, namely Gaussian,…
Background: Diagnostic PET image quality depends on the administered activity and acquisition time. However, minimizing these variables is desirable to reduce patient radiation exposure and radiopharmaceutical costs. PETfectior is an…
Clinical SPECT-MPI images of 345 patients acquired from a dedicated cardiac SPECT in list-mode format were retrospectively employed to predict normal-dose images from low-dose data at the half, quarter, and one-eighth-dose levels. A…
Positron emission tomography (PET) is widely used in various clinical applications, including cancer diagnosis, heart disease and neuro disorders. The use of radioactive tracer in PET imaging raises concerns due to the risk of radiation…
While compressed sensing (CS) based reconstructions have been developed for low-dose CBCT, a clear understanding on the relationship between the image quality and imaging dose at low dose levels is needed. In this paper, we qualitatively…
Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes…
An image or volume of interest in positron emission tomography (PET) is reconstructed from pairs of gamma rays emitted from a radioactive substance. Many image reconstruction methods are based on estimation of pixels or voxels on some…
Dose painting of hypoxic tumour sub-volumes using positron-emission tomography (PET) has been shown to improve tumour control in silico in several sites. Pancreatic cancer presents a more stringent challenge, given its proximity to critical…
One image processing application that is very helpful for humans is to improve image quality, poor image quality makes the image more difficult to interpret because the information conveyed by the image is reduced. In the process of the…
Statistical image reconstruction (SIR) methods for X-ray CT produce high-quality and accurate images, while greatly reducing patient exposure to radiation. When further reducing X-ray dose to an ultra-low level by lowering the tube current,…
Low-resolution and signal-dependent noise distribution in positron emission tomography (PET) images makes denoising process an inevitable step prior to qualitative and quantitative image analysis tasks. Conventional PET denoising methods…
Reducing scan times, radiation dose, and enhancing image quality for lower-performance scanners, are critical in low-dose PET imaging. Deep learning techniques have been investigated for PET image denoising. However, existing models have…
Positron emission tomography (PET) is a critical tool for diagnosing tumors and neurological disorders but poses radiation risks to patients, particularly to sensitive populations. While reducing injected radiation dose mitigates this risk,…
Anatomically guided PET reconstruction using MRI information has been shown to have the potential to improve PET image quality. However, these improvements are limited to PET scans with paired MRI information. In this work we employed a…
Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically…
To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most…
To acquire high-quality positron emission tomography (PET) images while reducing the radiation tracer dose, numerous efforts have been devoted to reconstructing standard-dose PET (SPET) images from low-dose PET (LPET). However, the success…
Cross-dose denoising for low-dose positron emission tomography (LDPET) has been proposed to address the limited generalization of models trained at a single noise level. However, neural networks trained on a specific dose level often fail…
A standard dose of radioactive tracer must be delivered into the patients body to obtain high-quality Positron Emission Tomography (PET) images for diagnostic purposes, which raises the risk of radiation harm. A reduced tracer dose, on the…
Tumor segmentation in oncological PET is challenging, a major reason being the partial-volume effects that arise due to low system resolution and finite voxel size. The latter results in tissue-fraction effects, i.e. voxels contain a…