相关论文: Improvement of phase sensitivity in SU(1,1) interf…
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input…
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity…
The accuracy of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shifters. Here, we employ coherent state mixed photon-added squeezed vacuum state as input into a…
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input…
A coherent seeded SU(1,1) interferometer provides a prominent technique in the field of precision measurement. We theoretically study the phase sensitivity of SU(1,1) interferometer with Kerr state seeding under single intensity and…
To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input…
We theoretically study the quantum Fisher information (QFI) of the SU(1,1) interferometer with phase shifts in two arms taking account of realistic noise effects. A generalized phase transform including the phase diffusion effect is…
We analyze theoretically and experimentally cases of asymmetric detection, stimulation, and loss within a quantum nonlinear interferometer of entangled pairs. We show that the visibility of the SU(1,1) interference directly discerns between…
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these…
Quantum metrology employs quantum resources to achieve measurement precision beyond classical limits. This work investigates a Mach--Zehnder interferometer incorporating a Kerr nonlinear phase shifter, with photon-added two-mode squeezed…
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a…
In this paper, we propose a nonlinear interferometer with feedback loops and explore its efficiency for phase estimation. We analyse two feedback schemes, one where both modes of the interferometer are fed-back into the device and another…
Measuring the phase of light is fundamental to optical imaging, sensing, and signal processing applications. Conventional optical phase measurements rely on multipath configurations, bulky interferometric setups, and computationally…
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…
The hybrid interferometer integrating an optical parametric amplifier and a beam splitter has the potential to outperform the SU(1,1) interferometer. However, photon loss remains a critical limitation for practical implementation. To…
Estimation of the phase delay between interferometer arms is the core of transmission phase microscopy. Such phase estimation may exhibit an error below the standard quantum (shot-noise) limit, if the input is an entangled two-mode state,…
An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel…
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beamsplitters replaced with parametric nonlinear optical processes. We consider the cases of bright and vacuum-seeded SU(1,1) interferometers…