中文
相关论文

相关论文: Performance study and calibration strategy of the …

200 篇论文

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…

A time-of-flight system with a plastic scintillator coupled to photomultipliers is developed for the external target facility (ETF). This system can satisfy the requirement of an ultrahigh vacuum ($\sim 10^{-9}$ mbar), a high counting rate…

仪器与探测器 · 物理学 2013-05-23 Zhang Xueheng , Yu Yuhong , Sun Zhiyu , Mao Ruishi , Wang Shitao , Zhou Yong , Yan Duo , Liu Longxiang

A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic…

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

仪器与探测器 · 物理学 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (gamma*beta=2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard `off the shelf' 4-gap…

A time-of-flight system was constructed for the STAR Experiment for the direct identification of hadrons produced in 197Au+197Au collisions at RHIC. The system consists of two separate detector subsystems, one called the pVPD (the "start"…

Efficiency and emission rate are two traditionally conflicting parameters in radiation detection, and achieving their simultaneous maximization could significantly advance ultrafast time-of-flight (ToF) technologies. In this study, we…

A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…

仪器与探测器 · 物理学 2024-08-19 N. Karpushkin , D. Finogeev , F. Guber , D. Lyapin , A. Makhnev , S. Morozov , D. Serebryakov

Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…

医学物理 · 物理学 2021-09-22 Emily Cloutier , Louis Archambault , Luc Beaulieu

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise…

仪器与探测器 · 物理学 2020-06-24 M. Bonesini , R. Benocci , R. Bertoni , A. Falcone , R. Mazza , M. Torti , A. Menegolli , G. L. Raselli , M. Rossella

Time-of-flight (tof) techniques are standard techniques in high energy physics to determine particles propagation directions. Since particles velocities are generally close to c, the speed of light, and detectors typical dimensions at the…

仪器与探测器 · 物理学 2014-02-11 J. Marteau , J. De Bremond D'ars , D. Gibert , K. Jourde , S. Gardien , C. Girerd , J. -C. Ianigro

The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The new version of the detector (called AMS-02) will be installed…

高能物理 - 实验 · 物理学 2017-08-23 L. Brocco , D. Casadei , F. Cindolo , A. Contin , G. Laurenti , G. Levi , A. Montanari , F. Palmonari , L. Patuelli , C. Sbarra , A. Zichichi

The Compressed Baryonic Matter spectrometer (CBM) is a future fixed-target heavy-ion experiment located at the Facility for Anti-proton and Ion Research (FAIR) in Darmstadt, Germany. The key element in CBM providing hadron identification at…

仪器与探测器 · 物理学 2020-01-29 I. Deppner , N. Herrmann

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

仪器与探测器 · 物理学 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

仪器与探测器 · 物理学 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long…

The light yield and the time resolution of different types of 3 m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9…

This paper aims at the problem of time-of-flight (ToF) estimation using channel state information (CSI) obtainable from commercialized MIMO-OFDM WLAN receivers. It was often claimed that the CSI phase is contaminated with errors of known…

信号处理 · 电气工程与系统科学 2019-02-27 Navid Tadayon , Muhammed T. Rahman , Shuo Han , Shahrokh Valaee , Wei Yu

We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…

仪器与探测器 · 物理学 2019-08-15 Jaroslav Zalesak