相关论文: Use Non-Energy-Curtailment Resources for Primary F…
Frequency stability of power systems becomes more vulnerable with the increase of solar photovoltaic (PV). Energy storage provides an option to mitigate the impact of high PV penetration. Using the U.S. Eastern Interconnection (EI) and…
Nonsynchronous generations such as photovoltaics (PVs) are expected to undermine bulk power systems (BPSs) frequency response at high penetration levels. Though the underlying mechanism has been relatively well understood, the accurate…
This paper studies the frequency response using PV. Multiple control strategies are considered and simulated in the high PV ERCOT model, including inertia control, synthetic governor control, and AGC control. The impact of different…
Solar photovoltaic (PV) generation is growing rapidly around the world. However, PV generation, based on inverter, is fundamentally different from conventional synchronous generators. It is of vital importance to understand the impacts of…
Due to the high solar irradiance or energy price, certain regions in the U.S. may reach 100% PV penetration and experience degradation of frequency response greater than the interconnection as a whole. Therefore, in this section, the 100%…
This letter proposes a distributed and adaptive demand response approach for primary frequency regulation in high-PV power systems. Using solar irradiance measurement at substations, the proposed approach allows accurate estimation of…
As renewable energy penetration increases and system inertia levels drop, primary frequency control is becoming a critical concern in relatively small interconnections such as the Electric Reliability Council of Texas (ERCOT). To address…
This paper studied the solar PV frequency control in the U.S. Eastern Interconnection (EI) and Texas Interconnection (ERCOT) systems. The studied frequency control approaches include droop frequency control, inertia control, and…
This study explores the impact of high PV penetration on the inter-area oscillation modes of large-scale power grids. A series of dynamic models with various PV penetration levels are developed based on a detailed model representing the…
Power systems are undergoing a transformation toward a low-carbon non-synchronous generation portfolio. A major concern for system planners and operators is the system dynamics in the high renewable penetration future. Because of the scale…
Traditionally, inertia in power systems has been determined by considering all the rotating masses directly connected to the grid. During the last decade, the integration of renewable energy sources, mainly photovoltaic installations and…
With the rising demand for solar energy installation, there is a pressing need for utilities to regulate the voltages at the distribution level. In grids with high penetration of photovoltaic (PV) systems, voltage fluctuations can occur at…
The growing penetration of distributed energy resources (DERs) has increased the complexity of the power system due to their intermittent characteristics and lower inertial response, such as photovoltaic (PV) systems and wind turbines. This…
Nowadays, power imbalance happens more frequently due to the more integration of renewable energy sources. Energy storage is a kind of devices that can charge energy at one time and discharge energy at another time. This function makes that…
In recent years, the contribution of renewable energy resources to the electrical grid has increased drastically; the most common of these are photovoltaic solar panels and wind turbines. These resources rely on inverters to interface with…
Large scale renewable energy integration is being planned for multiple power grids around the world. To achieve secure and stable grid operations, additional resources/reserves are needed to mitigate the inherent intermittency of renewable…
Environmental, economical and technical benefits of photovoltaic (PV) systems make them to be used in many countries. The main characteristic of PV systems is the fluctuations of their output power. Hence, high penetration of PV systems…
Nowadays, power system inertia is changing as a consequence of replacing conventional units by renewable energy sources, mainly wind and PV power plants. This fact affects significantly the grid frequency response under power imbalances. As…
Large-scale deployment of RES has led to significant generation shares of variable RES in power systems worldwide. RES units, notably inverter-connected wind turbines and PV that as such do not provide rotational inertia, are effectively…
Higher penetration of renewable generation will increase the demand for adequate (and cost-effective) controllable resources on the grid that can mitigate and contain the contingencies locally before it can cause a network-wide collapse.…