相关论文: Calibration of nuclear recoils at the 100 eV scale…
The emission of $\gamma$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus…
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by…
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV…
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy…
We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic Al$_2$O$_3$ detector developed by the NUCLEUS collaboration for the detection of reactor neutrinos via coherent elastic…
Detection of low-energy nuclear recoil events plays a central role in searches for particle dark matter interactions with atomic matter and studies of coherent neutrino scatters. Precise nuclear recoil calibration data allow the responses…
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This…
Nuclear reactors represent a promising neutrino source for CE$\nu$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can…
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass…
According to many dark matter models, a potential signal registered in a detector would feature a single-scattering nuclear recoil (NR). So, it is crucial to calibrate the detector's response to NR events. The conventional calibrations…
Low-energy nuclear recoils (NRs) are hard to measure because they produce few e$^{-}$/h$^+$ pairs in solids -- i.e. they have low "ionization yield". A silicon detector was exposed to thermal neutrons over 2.5\,live-days, probing NRs down…
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter…
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded.…
We determine the energy stored in the crystal defects induced by $\mathcal{O}(10-100)$\,eV nuclear recoils in low-threshold CaWO$_{4}$ cryogenic detectors. A Machine Learning interatomic potential is developed to perform molecular dynamics…
We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These…
We discuss prospects for probing short-range sterile neutrino oscillation using neutrino-nucleus coherent scattering with ultra-low energy ($\sim 10$ eV - 100 eV) recoil threshold cryogenic Ge detectors. The analysis is performed in the…
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma…
A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron…