Being low-level radiation exposure and less harmful to health, low-dose computed tomography (LDCT) has been widely adopted in the early screening of lung cancer and COVID-19. LDCT images inevitably suffer from the degradation problem caused…

图像与视频处理 · 电气工程与系统科学 2022-04-19 Kecheng Chen , Jiayu Sun , Jiang Shen , Jixiang Luo , Xinyu Zhang , Xuelin Pan , Dongsheng Wu , Yue Zhao , Miguel Bento , Yazhou Ren , Xiaorong Pu

Lowering the radiation dose in computed tomography (CT) can greatly reduce the potential risk to public health. However, the reconstructed images from the dose-reduced CT or low-dose CT (LDCT) suffer from severe noise, compromising the…

医学物理 · 物理学 2023-03-07 Zexin Lu , Wenjun Xia , Yongqiang Huang , Hongming Shan , Hu Chen , Jiliu Zhou , Yi Zhang

In coronary CT angiography, a series of CT images are taken at different levels of radiation dose during the examination. Although this reduces the total radiation dose, the image quality during the low-dose phases is significantly…

计算机视觉与模式识别 · 计算机科学 2019-03-06 Eunhee Kang , Hyun Jung Koo , Dong Hyun Yang , Joon Bum Seo , Jong Chul Ye

Most of the Deep Neural Networks (DNNs) based CT image denoising literature shows that DNNs outperform traditional iterative methods in terms of metrics such as the RMSE, the PSNR and the SSIM. In many instances, using the same metrics, the…

计算机视觉与模式识别 · 计算机科学 2021-11-19 Prabhat KC , Rongping Zeng , M. Mehdi Farhangi , Kyle J. Myers

The use of deep learning has successfully solved several problems in the field of medical imaging. Deep learning has been applied to the CT denoising problem successfully. However, the use of deep learning requires large amounts of data to…

图像与视频处理 · 电气工程与系统科学 2022-04-04 Mayank Patwari , Ralf Gutjahr , Rainer Raupach , Andreas Maier

Deep learning approaches in image processing predominantly resort to supervised learning. A majority of methods for image denoising are no exception to this rule and hence demand pairs of noisy and corresponding clean images. Only recently…

图像与视频处理 · 电气工程与系统科学 2020-10-02 Priyatham Kattakinda , A. N. Rajagopalan

Low-dose computed tomography (LDCT) denoising is an important problem in CT research. Compared to the normal dose CT (NDCT), LDCT images are subjected to severe noise and artifacts. Recently in many studies, vision transformers have shown…

图像与视频处理 · 电气工程与系统科学 2023-03-29 Dayang Wang , Fenglei Fan , Zhan Wu , Rui Liu , Fei Wang , Hengyong Yu

Low Dose Computed Tomography (LDCT) is clinically desirable due to the reduced radiation to patients. However, the quality of LDCT images is often sub-optimal because of the inevitable strong quantum noise. Inspired by their unprecedent…

图像与视频处理 · 电气工程与系统科学 2021-02-02 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Computed tomography (CT) is a popular medical imaging modality in clinical applications. At the same time, the x-ray radiation dose associated with CT scans raises public concerns due to its potential risks to the patients. Over the past…

计算机视觉与模式识别 · 计算机科学 2018-08-13 Chenyu You , Qingsong Yang , Hongming Shan , Lars Gjesteby , Guang Li , Shenghong Ju , Zhuiyang Zhang , Zhen Zhao , Yi Zhang , Wenxiang Cong , Ge Wang

Low dose computed tomography is a mainstream for clinical applications. How-ever, compared to normal dose CT, in the low dose CT (LDCT) images, there are stronger noise and more artifacts which are obstacles for practical applications. In…

图像与视频处理 · 电气工程与系统科学 2021-06-10 Dayang Wang , Zhan Wu , Hengyong Yu

Computed tomography (CT) is routinely used for three-dimensional non-invasive imaging. Numerous data-driven image denoising algorithms were proposed to restore image quality in low-dose acquisitions. However, considerably less research…

Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses…

图像与视频处理 · 电气工程与系统科学 2024-07-01 Yucheng Lu , Zhixin Xu , Moon Hyung Choi , Jimin Kim , Seung-Won Jung

This work tackles the issue of noise removal from images, focusing on the well-known DCT image denoising algorithm. The latter, stemming from signal processing, has been well studied over the years. Though very simple, it is still used in…

图像与视频处理 · 电气工程与系统科学 2022-07-13 Sébastien Herbreteau , Charles Kervrann

X-ray Computed Tomography (CT) is an important tool in medical imaging to obtain a direct visualization of patient anatomy. However, the x-ray radiation exposure leads to the concern of lifetime cancer risk. Low-dose CT scan can reduce the…

医学物理 · 物理学 2018-10-30 Guoyang Ma , Chenyang Shen , Xun Jia

In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises the signal-to-noise…

图像与视频处理 · 电气工程与系统科学 2024-07-02 Haoyu Zhao , Yuliang Gu , Zhou Zhao , Bo Du , Yongchao Xu , Rui Yu

Low-dose computed tomography (LDCT) is critical for minimizing radiation exposure, but it often leads to increased noise and reduced image quality. Traditional denoising methods, such as iterative optimization or supervised learning, often…

计算机视觉与模式识别 · 计算机科学 2025-09-23 Debopom Sutradhar , Ripon Kumar Debnath , Mohaimenul Azam Khan Raiaan , Yan Zhang , Reem E. Mohamed , Sami Azam

The denoising of magnetic resonance (MR) images is a task of great importance for improving the acquired image quality. Many methods have been proposed in the literature to retrieve noise free images with good performances. Howerever, the…

计算机视觉与模式识别 · 计算机科学 2018-02-01 Dongsheng Jiang , Weiqiang Dou , Luc Vosters , Xiayu Xu , Yue Sun , Tao Tan

While various deep learning methods were proposed for low-dose computed tomography (CT) denoising, they often suffer from over-smoothing, blurring, and lack of explainability. To alleviate these issues, we propose a plug-and-play…

图像与视频处理 · 电气工程与系统科学 2024-03-12 Zhihao Chen , Tao Chen , Chenhui Wang , Chuang Niu , Ge Wang , Hongming Shan

Computed Tomography (CT) is a vital diagnostic tool in clinical practice, yet the health risks associated with ionizing radiation cannot be overlooked. Low-dose CT (LDCT) helps mitigate radiation exposure but simultaneously leads to reduced…

计算机视觉与模式识别 · 计算机科学 2025-11-20 Guoliang Gong , Man Yu

Traditional model-based image reconstruction (MBIR) methods combine forward and noise models with simple object priors. Recent application of deep learning methods for image reconstruction provides a successful data-driven approach to…

图像与视频处理 · 电气工程与系统科学 2023-11-22 Ling Chen , Zhishen Huang , Yong Long , Saiprasad Ravishankar