In this series of papers, we present new methods of frequency- and time-dependent instrumental polarization calibration for Very Long Baseline Interferometry (VLBI). In most existing calibration tools and pipelines, it has been assumed that…

天体物理仪器与方法 · 物理学 2023-10-06 Jongho Park , Keiichi Asada , Do-Young Byun

We present a new method of time-dependent instrumental polarization calibration for Very Long Baseline Interferometry (VLBI). This method has been implemented in the recently developed polarization calibration pipeline GPCAL. Instrumental…

天体物理仪器与方法 · 物理学 2023-10-06 Jongho Park , Keiichi Asada , Do-Young Byun

The linear polarization images of the jet in the giant elliptical galaxy M87 have previously been observed with Very Long Baseline Array at 7 mm. They exhibit a complex polarization structure surrounding the optically thick and compact…

Very long baseline interferometry (VLBI) is a powerful technique that can achieve sub-milliarcsecond resolution. However, it requires complex and often manual post-correlation calibration to correct for instrumental, geometric, and…

天体物理仪器与方法 · 物理学 2025-12-01 Diego Álvarez-Ortega , Carolina Casadio , Felix M. Pötzl , Avinash Kumar , Michael Janssen

We report the development of a semi-automatic pipeline for the calibration of 86 GHz full-polarization observations performed with the Global Millimeter-VLBI array (GMVA) and describe the calibration strategy followed in the data reduction.…

Context. The current algorithms used for the calibration and analysis of very long baseline interferometry (VLBI) networks that only use linear polarizers (as is the case of the VLBI Global Observing System, VGOS) do not properly account…

天体物理仪器与方法 · 物理学 2024-06-19 V. Pérez-Díez , I. Martí-Vidal , E. Albentosa-Ruiz , J. González-García , F. Jaron , T. Savolainen , M. H. Xu , R. Bachiller

Extracting polarimetric information from very long baseline interferometry (VLBI) data is demanding but vital for understanding the synchrotron radiation process and the magnetic fields of celestial objects, such as active galactic nuclei…

The calibration of Very Long Baseline Interferometry (VLBI) data has long been a time consuming process. The Korean VLBI Network (KVN) is a simple array consisting of three identical antennas. Because four frequencies are observed…

天体物理仪器与方法 · 物理学 2017-08-23 Jeffrey A. Hodgson , Sang-Sung Lee , Guang-Yao Zhao , Juan-Carlos Algaba , Youngjoo Yun , Taehyun Jung , Do-Young Byun

The calibration and analysis of polarization observations in Very Long Baseline Interferometry (VLBI) requires the use of specific algorithms that suffer from several limitations, closely related to assumptions in the data properties that…

天体物理仪器与方法 · 物理学 2021-02-10 Ivan Marti-Vidal , Alejandro Mus , Michael Janssen , Pablo de Vicente , Javier Gonzalez

We describe a flagging and calibration pipeline intended for making quick look images from GMRT data. The package identifies and flags corrupted visibilities, computes calibration solutions and interpolates these onto the target source.…

天体物理仪器与方法 · 物理学 2012-03-20 Jayanti Prasad , Jayaram Chengalur

Self-calibration methods with the CLEAN algorithm have been widely employed in Very Long Baseline Interferometry (VLBI) data processing in order to correct antenna-based amplitude and phase corruptions present in the data. However, human…

Currently, HOPS and AIPS are the primary choices for the time-consuming process of (millimeter) Very Long Baseline Interferometry (VLBI) data calibration. However, for a full end-to-end pipeline, they either lack the ability to perform…

天体物理仪器与方法 · 物理学 2022-06-29 M. Janssen , C. Goddi , H. Falcke , D. van Rossum , I. van Bemmel , M. Kettenis , D. Small , I. Martí-Vidal

(Abridged) The CASA software suite, can now reduce very long baseline interferometry (VLBI) data with the recent addition of a fringe fitter. Here, we present the Radboud PIpeline for the Calibration of high Angular Resolution Data…

We present the design and implementation of an automated data calibration and reduction pipeline for very-long-baseline interferometric (VLBI) observations taken at millimeter wavelengths. These short radio-wavelengths provide the best…

The East Asia VLBI Network (EAVN) has recently enabled dual-polarization observations at $22$ and $43\,\mathrm{GHz}$. We present the first systematic verification of its polarimetric performance using EAVN observations of M87, 3C 279, 3C…

The Cosmic Microwave Background (CMB) radiation offers a unique window into the early Universe, facilitating precise examinations of fundamental cosmological theories. However, the quest for detecting B-modes in the CMB, predicted by…

Calibrating large volumes of Very Long Baseline Interferometry (VLBI) data traditionally requires significant human intervention at every stage. While the Common Astronomy Software Applications (CASA) package is the standard data reduction…

天体物理仪器与方法 · 物理学 2026-04-21 A. Kumar , C. Casadio , M. Janssen , D. Álvarez-Ortega , F. M. Pötzl

This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from…

宇宙学与河外天体物理 · 物理学 2016-09-21 Planck Collaboration , R. Adam , P. A. R. Ade , N. Aghanim , M. Arnaud , M. Ashdown , J. Aumont , C. Baccigalupi , A. J. Banday , R. B. Barreiro , N. Bartolo , E. Battaner , K. Benabed , A. Benoît , A. Benoit-Lévy , J. -P. Bernard , M. Bersanelli , B. Bertincourt , P. Bielewicz , J. J. Bock , L. Bonavera , J. R. Bond , J. Borrill , F. R. Bouchet , F. Boulanger , M. Bucher , C. Burigana , E. Calabrese , J. -F. Cardoso , A. Catalano , A. Challinor , A. Chamballu , H. C. Chiang , P. R. Christensen , D. L. Clements , S. Colombi , L. P. L. Colombo , C. Combet , F. Couchot , A. Coulais , B. P. Crill , A. Curto , F. Cuttaia , L. Danese , R. D. Davies , R. J. Davis , P. de Bernardis , A. de Rosa , G. de Zotti , J. Delabrouille , J. -M. Delouis , F. -X. Désert , J. M. Diego , H. Dole , S. Donzelli , O. Doré , M. Douspis , A. Ducout , X. Dupac , G. Efstathiou , F. Elsner , T. A. Enßlin , H. K. Eriksen , E. Falgarone , J. Fergusson , F. Finelli , O. Forni , M. Frailis , A. A. Fraisse , E. Franceschi , A. Frejsel , S. Galeotta , S. Galli , K. Ganga , T. Ghosh , M. Giard , Y. Giraud-Héraud , E. Gjerløw , J. González-Nuevo , K. M. Górski , S. Gratton , A. Gruppuso , J. E. Gudmundsson , F. K. Hansen , D. Hanson , D. L. Harrison , S. Henrot-Versillé , D. Herranz , S. R. Hildebrandt , E. Hivon , M. Hobson , W. A. Holmes , A. Hornstrup , W. Hovest , K. M. Huffenberger , G. Hurier , A. H. Jaffe , T. R. Jaffe , W. C. Jones , M. Juvela , E. Keihänen , R. Keskitalo , T. S. Kisner , R. Kneissl , J. Knoche , M. Kunz , H. Kurki-Suonio , G. Lagache , J. -M. Lamarre , A. Lasenby , M. Lattanzi , C. R. Lawrence , M. Le Jeune , J. P. Leahy , E. Lellouch , R. Leonardi , J. Lesgourgues , F. Levrier , M. Liguori , P. B. Lilje , M. Linden-Vørnle , M. López-Caniego , P. M. Lubin , J. F. Macías-Pérez , G. Maggio , D. Maino , N. Mandolesi , A. Mangilli , M. Maris , P. G. Martin , E. Martínez-González , S. Masi , S. Matarrese , P. McGehee , A. Melchiorri , L. Mendes , A. Mennella , M. Migliaccio , S. Mitra , M. -A. Miville-Deschênes , A. Moneti , L. Montier , R. Moreno , G. Morgante , D. Mortlock , A. Moss , S. Mottet , D. Munshi , J. A. Murphy , P. Naselsky , F. Nati , P. Natoli , C. B. Netterfield , H. U. Nørgaard-Nielsen , F. Noviello , D. Novikov , I. Novikov , C. A. Oxborrow , F. Paci , L. Pagano , F. Pajot , D. Paoletti , F. Pasian , G. Patanchon , T. J. Pearson , O. Perdereau , L. Perotto , F. Perrotta , V. Pettorino , F. Piacentini , M. Piat , E. Pierpaoli , D. Pietrobon , S. Plaszczynski , E. Pointecouteau , G. Polenta , G. W. Pratt , G. Prézeau , S. Prunet , J. -L. Puget , J. P. Rachen , M. Reinecke , M. Remazeilles , C. Renault , A. Renzi , I. Ristorcelli , G. Rocha , C. Rosset , M. Rossetti , G. Roudier , B. Rusholme , M. Sandri , D. Santos , A. Sauvé , M. Savelainen , G. Savini , D. Scott , M. D. Seiffert , E. P. S. Shellard , L. D. Spencer , V. Stolyarov , R. Stompor , R. Sudiwala , D. Sutton , A. -S. Suur-Uski , J. -F. Sygnet , J. A. Tauber , L. Terenzi , L. Toffolatti , M. Tomasi , M. Tristram , M. Tucci , J. Tuovinen , L. Valenziano , J. Valiviita , B. Van Tent , L. Vibert , P. Vielva , F. Villa , L. A. Wade , B. D. Wandelt , R. Watson , I. K. Wehus , D. Yvon , A. Zacchei , A. Zonca

We present full polarization Very Long Baseline Array (VLBA) observations at 5 GHz and 15 GHz of 24 compact active galactic nuclei (AGN). These sources were observed as part of a pilot project to demonstrate the feasibility of conducting a…

Accurate camera calibration is crucial for various computer vision applications. However, measuring calibration accuracy in the real world is challenging due to the lack of datasets with ground truth to evaluate them. In this paper, we…

计算机视觉与模式识别 · 计算机科学 2024-08-20 Lala Shakti Swarup Ray , Bo Zhou , Lars Krupp , Sungho Suh , Paul Lukowicz
‹ 上一页 1 2 3 10 下一页 ›