相关论文: Compressed Fourier-Domain Convolutional Beamformin…
Sonography techniques use multiple transducer elements for tissue visualization. Signals detected at each element are sampled prior to digital beamforming. The sampling rates required to perform high resolution digital beamforming are…
The standard technique used by commercial medical ultrasound systems to form B-mode images is delay and sum (DAS) beamforming. However, DAS often results in limited image resolution and contrast, which are governed by the center frequency…
Sonography techniques use multiple transducer elements for tissue visualization. Signals detected at each element are sampled prior to digital beamforming. The required sampling rates are up to 4 times the Nyquist rate of the signal and…
The most common technique for generating B-mode ultrasound (US) images is delay and sum (DAS) beamforming, where the signals received at the transducer array are sampled before an appropriate delay is applied. This necessitates sampling…
One of the key steps in ultrasound image formation is digital beamforming of signals sampled by several transducer elements placed upon an array. High-resolution digital beamforming introduces the demand for sampling rates significantly…
Ultrasound B-Mode images are created from data obtained from each element in the transducer array in a process called beamforming. The beamforming goal is to enhance signals from specified spatial locations, while reducing signal from all…
Ultrasound (US) imaging is based on the time-reversal principle, in which individual channel RF measurements are back-propagated and accumulated to form an image after applying specific delays. While this time reversal is usually…
In ultrasound (US) imaging, various types of adaptive beamforming techniques have been investigated to improve the resolution and contrast-to-noise ratio of the delay and sum (DAS) beamformers. Unfortunately, the performance of these…
We present a compressive beamforming method for coherent plane-wave compounding (CPWC) ultrasound imaging based on a far-field decomposition of the received radiofrequency (RF) data into virtual plane waves. This decomposition recasts the…
Emerging sonography techniques often imply increasing in the number of transducer elements involved in the imaging process. Consequently, larger amounts of data must be acquired and processed by the beamformer. The significant growth in the…
In ultrasound (US) imaging, individual channel RF measurements are back-propagated and accumulated to form an image after applying specific delays. While this time reversal is usually implemented using a hardware- or software-based…
Traditional beamforming of medical ultrasound images relies on sampling rates significantly higher than the actual Nyquist rate of the received signals. This results in large amounts of data to store and process, imposing hardware and…
Emerging sonography techniques often require increasing the number of transducer elements involved in the imaging process. Consequently, larger amounts of data must be acquired and processed. The significant growth in the amounts of data…
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of…
Automatic learning algorithms for improving the image quality of diagnostic B-mode ultrasound (US) images have been gaining popularity in the recent past. In this work, a novel convolutional neural network (CNN) is trained using time of…
Delay-and-sum (DAS) is the most widespread digital beamformer in high-frame-rate ultrasound imaging. Its implementation is simple and compatible with real-time applications. In this viewpoint article, we describe the fundamentals of DAS…
In many ultrasonic imaging systems, data acquisition and image formation are performed on separate computing devices. Data transmission is becoming a bottleneck, thus, efficient data compression is essential. Compression rates can be…
Image reconstruction from radio-frequency data is pivotal in ultrafast plane wave ultrasound imaging. Unlike the conventional delay-and-sum (DAS) technique, which relies on somewhat imprecise assumptions, deep learning-based methods perform…
The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small…
Modern imaging systems typically use single-carrier short pulses for transducer excitation. Coded signals together with pulse compression are successfully used in radar and communication to increase the amount of transmitted energy.…