中文
相关论文

相关论文: C-Arm Non-Circular Orbits: Geometric Calibration, …

200 篇论文

Image-guided navigation of catheter devices to anatomic targets within large 3D cardiac chambers and vessels is challenging in the interventional setting due to the limitations of a conventional 2D x-ray projection format. Scanning-beam…

医学物理 · 物理学 2024-03-26 Jordan M. Slagowski

Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally…

计算机视觉与模式识别 · 计算机科学 2026-02-10 Johannes Thalhammer , Tina Dorosti , Sebastian Peterhansl , Daniela Pfeiffer , Franz Pfeiffer , Florian Schaff

In several image acquisition and processing steps of X-ray radiography, knowledge of the existence of metal implants and their exact position is highly beneficial (e.g. dose regulation, image contrast adjustment). Another application which…

图像与视频处理 · 电气工程与系统科学 2022-03-18 Fuxin Fan , Ludwig Ritschl , Marcel Beister , Ramyar Biniazan , Björn Kreher , Tristan M. Gottschalk , Steffen Kappler , Andreas Maier

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…

医学物理 · 物理学 2025-05-27 Yang Zou , Meili Qi , Jianhua Zhang , Difei Zhang , Shuwei Wang , Jiale Zhang , Shengkun Yao , Huaidong Jiang

\textbf{Purpose:} C-arm fluoroscopy's 3D reconstruction relies on accurate intrinsic calibration, which is often challenging in clinical practice. This study ensures high-precision reconstruction accuracy by re-optimizing the extrinsic…

计算机视觉与模式识别 · 计算机科学 2026-03-17 Lin Li , Benjamin Aubert , Paul Kemper , Aric Plumley

Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…

医学物理 · 物理学 2017-08-02 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo

Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…

图像与视频处理 · 电气工程与系统科学 2024-02-12 Dhruvi Shah , Shruti Mehta , Ashish Agrawal , Shishir Purohit , Bhaskar Chaudhury

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the…

图像与视频处理 · 电气工程与系统科学 2024-12-30 Haotian Zhao , Ruifeng Chen , Jing Yan , Juan Feng , Jun Xiang , Yang Chen , Dong Liang , Yinsheng Li

In conventional 2D DCE-US, motion correction algorithms take advantage of accompanying side-by-side anatomical Bmode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side Bmode…

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng

We propose an atlas-based method to segment the intracochlear anatomy (ICA) in the post-implantation CT (Post-CT) images of cochlear implant (CI) recipients that preserves the point-to-point correspondence between the meshes in the atlas…

图像与视频处理 · 电气工程与系统科学 2021-07-12 Jianing Wang , Dingjie Su , Yubo Fan , Srijata Chakravorti , Jack H. Noble , Benoit M. Dawant

Cardiac cine magnetic resonance imaging (MRI) is one of the important means to assess cardiac functions and vascular abnormalities. Mitigating artifacts arising during image reconstruction and accelerating cardiac cine MRI acquisition to…

图像与视频处理 · 电气工程与系统科学 2024-07-03 Xiaoxiang Han , Yang Chen , Qiaohong Liu , Yiman Liu , Keyan Chen , Yuanjie Lin , Weikun Zhang

Sparse-view computed tomography (CT) has been adopted as an important technique for speeding up data acquisition and decreasing radiation dose. However, due to the lack of sufficient projection data, the reconstructed CT images often…

图像与视频处理 · 电气工程与系统科学 2023-06-27 Hong Wang , Minghao Zhou , Dong Wei , Yuexiang Li , Yefeng Zheng

The presence of inhomogeneous media between optical sensors and objects leads to distorted imaging outputs, significantly complicating downstream image-processing tasks. A key challenge in image restoration is the lack of high-quality,…

计算机视觉与模式识别 · 计算机科学 2025-04-22 Chu Chen , Han Zhang , Lok Ming Lui

Interventional C-arm imaging is crucial to percutaneous orthopedic procedures as it enables the surgeon to monitor the progress of surgery on the anatomy level. Minimally invasive interventions require repeated acquisition of X-ray images…

计算机视觉与模式识别 · 计算机科学 2018-06-26 Mathias Unberath , Javad Fotouhi , Jonas Hajek , Andreas Maier , Greg Osgood , Russell Taylor , Mehran Armand , Nassir Navab

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in…

图像与视频处理 · 电气工程与系统科学 2026-03-30 Naruki Murahashi , Mitsuhiro Nakamura , Megumi Nakao

For extending CT field-of-view to perform non-destructive testing, the Symmetric Multi-Linear trajectory Computed Tomography (SMLCT) has been developed as a successful example of non-standard CT scanning modes. However, inevitable geometric…

计算机视觉与模式识别 · 计算机科学 2024-08-28 Zhisheng Wang , Yanxu Sun , Shangyu Li , Legeng Lin , Shunli Wang , Junning Cui

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

医学物理 · 物理学 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang