相关论文: Deep Sinogram Completion with Image Prior for Meta…

200 篇论文

An attention guided scheme for metal artifact correction in MRI using deep neural network is proposed in this paper. The inputs of the networks are two distorted images obtained with dual-polarity readout gradients. With MR image generation…

图像与视频处理 · 电气工程与系统科学 2019-10-22 Jee Won Kim , Kinam Kwon , Byungjai Kim , HyunWook Park

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

图像与视频处理 · 电气工程与系统科学 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

A CT image can be well reconstructed when the sampling rate of the sinogram satisfies the Nyquist criteria and the sampled signal is noise-free. However, in practice, the sinogram is usually contaminated by noise, which degrades the quality…

图像与视频处理 · 电气工程与系统科学 2020-01-22 Wei Wang , Xiang-Gen Xia , Chuanjiang He , Zemin Ren , Jian Lu , Tianfu Wang , Baiying Lei

The sparse-views x-ray computed tomography (CT) is essential for medical diagnosis and industrial nondestructive testing. However, in particular, the reconstructed image usually suffers from complex artifacts and noise, when the sampling is…

医学物理 · 物理学 2019-10-08 Genwei Ma , Yining Zhu , Xing Zhao

High density implants such as metals often lead to serious artifacts in the reconstructed CT images which hampers the accuracy of image based diagnosis and treatment planning. In this paper, we propose a novel wavelet frame based CT image…

医学物理 · 物理学 2017-11-21 Haimiao Zhang , Bin Dong , Baodong Liu

In computer tomography, due to the presence of metal implants in the patient body, reconstructed images will suffer from metal artifacts. In order to reduce metal artifacts, metals are typically removed in projection images. Therefore, the…

计算机视觉与模式识别 · 计算机科学 2020-05-05 Lin Yuan , Yixing Huang , Andreas Maier

X-ray CT often suffers from shadowing and streaking artifacts in the presence of metallic materials, which severely degrade imaging quality. Physically, the linear attenuation coefficients (LACs) of metals vary significantly with X-ray…

计算机视觉与模式识别 · 计算机科学 2025-01-16 Qing Wu , Xu Guo , Lixuan Chen , Yanyan Liu , Dongming He , Xudong Wang , Xueli Chen , Yifeng Zhang , S. Kevin Zhou , Jingyi Yu , Yuyao Zhang

Metal artefacts in CT images may disrupt image quality and interfere with diagnosis. Recently many deep-learning-based CT metal artefact reduction (MAR) methods have been proposed. Current deep MAR methods may be troubled with domain gap…

计算机视觉与模式识别 · 计算机科学 2021-11-29 Muge Du , Kaichao Liang , Yinong Liu , Yuxiang Xing

X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the…

数值分析 · 数学 2016-02-24 Jae Kyu Choi , Bin Dong , Xiaoqun Zhang

Emerging neural reconstruction techniques based on tomography (e.g., NeRF, NeAT, and NeRP) have started showing unique capabilities in medical imaging. In this work, we present a novel Polychromatic neural representation (Polyner) to tackle…

图像与视频处理 · 电气工程与系统科学 2023-10-03 Qing Wu , Lixuan Chen , Ce Wang , Hongjiang Wei , S. Kevin Zhou , Jingyi Yu , Yuyao Zhang

Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…

医学物理 · 物理学 2017-08-02 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo

Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential pre-processing step…

计算机视觉与模式识别 · 计算机科学 2016-03-15 Faisal Mahmood , Nauman Shahid , Pierre Vandergheynst , Ulf Skoglund

Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…

图像与视频处理 · 电气工程与系统科学 2024-02-12 Dhruvi Shah , Shruti Mehta , Ashish Agrawal , Shishir Purohit , Bhaskar Chaudhury

In this paper, we first propose a variational model for the limited-angle computed tomography (CT) image reconstruction and then convert the model into an end-to-end deep network.We use the penalty method to solve the model and divide it…

图像与视频处理 · 电气工程与系统科学 2020-08-11 Wei Wang , Xiang-Gen Xia , Chuanjiang He , Zemin Ren , Jian Lu , Tianfu Wang , Baiying Lei

Motion during acquisition of a set of projections can lead to significant motion artifacts in computed tomography reconstructions despite fast acquisition of individual views. In cases such as cardiac imaging, motion may be unavoidable and…

图像与视频处理 · 电气工程与系统科学 2022-01-19 Kunal Gupta , Brendan Colvert , Francisco Contijoch

Sparse-view computed tomography (CT) has been adopted as an important technique for speeding up data acquisition and decreasing radiation dose. However, due to the lack of sufficient projection data, the reconstructed CT images often…

图像与视频处理 · 电气工程与系统科学 2023-06-27 Hong Wang , Minghao Zhou , Dong Wei , Yuexiang Li , Yefeng Zheng

In computed tomography imaging, metal implants frequently generate severe artifacts that compromise image quality and hinder diagnostic accuracy. There are three main challenges in the existing methods: the deterioration of organ and tissue…

计算机视觉与模式识别 · 计算机科学 2026-04-09 Weikai Qu , Sijun Liang , Xianfeng Li , Cheng Pan , An Yan , Ahmed Elazab , Shanzhou Niu , Dong Zeng , Xiang Wan , Changmiao Wang

CT images corrupted by metal artifacts have serious negative effects on clinical diagnosis. Considering the difficulty of collecting paired data with ground truth in clinical settings, unsupervised methods for metal artifact reduction are…

计算机视觉与模式识别 · 计算机科学 2023-07-31 Wangduo Xie , Matthew B. Blaschko

Positron emission tomography (PET) scanners continue to increase sensitivity and axial coverage by adding an ever expanding array of block detectors. As they age, one or more block detectors may lose sensitivity due to a malfunction or…

医学物理 · 物理学 2019-10-17 William Whiteley , Jens Gregor

As the medical usage of computed tomography (CT) continues to grow, the radiation dose should remain at a low level to reduce the health risks. Therefore, there is an increasing need for algorithms that can reconstruct high-quality images…

图像与视频处理 · 电气工程与系统科学 2021-03-10 Davood Karimi , Rabab K. Ward