中文
相关论文

相关论文: Accelerometric Method for Cuffless Continuous Bloo…

200 篇论文

This paper presents a novel blood pressure (BP) estimation method based on pulse transit time (PTT) and pulse arrival time (PAT) to estimate the systolic BP (SBP) and the diastolic BP (DBP). A data acquisition hardware is designed for…

信号处理 · 电气工程与系统科学 2019-05-08 Amirhossein Esmaili , Mohammad Kachuee , Mahdi Shabany

Cardiovascular disease (CVD) is a leading cause of morbidity and mortality worldwide, and sustained hypertension is an often silent risk factor, making cuffless continuous blood pressure (BP) monitoring with wearable devices important for…

信号处理 · 电气工程与系统科学 2025-12-02 Yiqiao Chen , Fazheng Xu , Zijian Huang , Juchi He , Zhenghui Feng

This paper presents a novel approach based on pulse transit time (PTT) for the estimation of blood pressure (BP). In order to achieve this goal, a data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG)…

信号处理 · 电气工程与系统科学 2019-05-08 Amirhossein Esmaili , Mohammad Kachuee , Mahdi Shabany

The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them…

信号处理 · 电气工程与系统科学 2023-05-30 Lirui Xu , Pang Wu , Pan Xia , Fanglin Geng , Peng Wang , Xianxiang Chen , Zhenfeng Li , Lidong Du , Shuping Liu , Li Li , Hongbo Chang , Zhen Fang

Extensive research has been performed on continuous, non-invasive, cuffless blood pressure (BP) measurement using artificial intelligence algorithms. This approach involves extracting certain features from physiological signals like ECG,…

医学物理 · 物理学 2023-04-03 Ali Farki , Reza Baradaran Kazemzadeh , Elham Akhondzadeh Noughabi

This research presents a novel method for noninvasive arterial blood pressure ABP prediction using speech signals employing a BERT based regression model Arterial blood pressure is a vital indicator of cardiovascular health and accurate…

机器学习 · 计算机科学 2025-09-25 Kainat

Goal: Although photoplethysmogram (PPG) and electrocardiogram (ECG) signals can be used to estimate blood pressure (BP) by extracting various features, the changes in morphological contours of both PPG and ECG signals due to various…

信号处理 · 电气工程与系统科学 2018-11-07 Md. Sayed Tanveer , Md. Kamrul Hasan

Continuous and noninvasive monitoring of blood pressure has numerous clinical and fitness applications. Current methods of continuous measurement of blood pressure are either invasive and/or require expensive equipment. Therefore, we…

信号处理 · 电气工程与系统科学 2018-11-16 Armin Soltan Zadi , Raichel Alex , Rong Zhang , Donald E. Watenpaugh , Khosrow Behbehani

Cuffless blood pressure (BP) estimation based on Pulse Transit Time (PTT) has emerged as a promising solution for continuous health monitoring. However, conventional models relying on the Moens-Korteweg equation often fail during rapid…

人机交互 · 计算机科学 2026-05-01 Boyuan Gu , Yijin Yang , Shuaiqi Cheng , Xiaorong Ding

Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present the first AI-enabled mmWave system…

Hypertension is a potentially unsafe health ailment, which can be indicated directly from the Blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based…

Accurate and continuous blood pressure (BP) monitoring is essential to the early prevention of cardiovascular diseases. Non-invasive and cuff-less BP estimation algorithm has gained much attention in recent years. Previous studies have…

机器学习 · 计算机科学 2023-11-27 Bufang Yang , Le Liu , Wenxuan Wu , Mengliang Zhou , Hongxing Liu , Xinbao Ning

We develop and evaluate two novel purpose-built deep learning (DL) models for synthesis of the arterial blood pressure (ABP) waveform in a cuff-less manner, using a single-site photoplethysmography (PPG) signal. We train and evaluate our DL…

信号处理 · 电气工程与系统科学 2024-06-11 Muhammad Wasim Nawaz , Muhammad Ahmad Tahir , Ahsan Mehmood , Muhammad Mahboob Ur Rahman , Kashif Riaz , Qammer H. Abbasi

Photoplethysmogram (PPG) signal-based blood pressure (BP) estimation is a promising candidate for modern BP measurements, as PPG signals can be easily obtained from wearable devices in a non-invasive manner, allowing quick BP measurement.…

信号处理 · 电气工程与系统科学 2021-03-01 Hyeongju Kim , Woo Hyun Kang , Hyeonseung Lee , Nam Soo Kim

Cuffless blood pressure screening based on easily acquired photoplethysmography (PPG) signals offers a practical pathway toward scalable cardiovascular health assessment. Despite rapid progress, existing PPG-based blood pressure estimation…

机器学习 · 计算机科学 2026-02-05 Neville Mathew , Yidan Shen , Renjie Hu , Maham Rahimi , George Zouridakis

Blood pressure (BP) is one of the most influential bio-markers for cardiovascular diseases and stroke; therefore, it needs to be regularly monitored to diagnose and prevent any advent of medical complications. Current cuffless approaches to…

机器学习 · 计算机科学 2021-11-30 Rishi Vardhan K , Vedanth S , Poojah G , Abhishek K , Nitish Kumar M , Vineeth Vijayaraghavan

Documentation of epileptic seizures plays an essential role in planning medical therapy. Solutions for automated epileptic seizure detection can help improve the current problem of incomplete and erroneous manual documentation of epileptic…

计算机视觉与模式识别 · 计算机科学 2021-07-14 Eric Fiege , Salima Houta , Pinar Bisgin , Rainer Surges , Falk Howar

Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low…

机器学习 · 计算机科学 2022-01-03 Soheil Zabihi , Elahe Rahimian , Fatemeh Marefat , Amir Asif , Pedram Mohseni , Arash Mohammadi

Background and Objectives: In a significant portion of surgeries, blood pressure (BP) is often measured non-invasively in an intermittent manner. This practice has a risk of missing clinically relevant BP changes between two adjacent…

Comparison of tacho-oscillographic and oscillometric methods for human blood pressure measurement with cuff occlusion in the same device at the same time is described. For this purpose the measurement system and software for signal…

系统与控制 · 计算机科学 2015-06-22 Maksym Sikorsky , Anton Soroka , Vitaliy Mosiychuk , Oleg Sharpan
‹ 上一页 1 2 3 10 下一页 ›