相关论文: Design of Transmission Line and Electromagnetic Fi…
Partial discharge (PD) is a common indication of faults in power systems, such as generators, and cables. These PD can eventually result in costly repairs and substantial power outages. PD detection traditionally relies on hand-crafted…
The detection and characterization of partial discharge (PD) are crucial for the insulation diagnosis of overhead lines with covered conductors. With the release of a large dataset containing thousands of naturally obtained high-frequency…
Nowadays, aerial covered conductors (CC) are increasingly used in many places of the world due to their higher operational reliability, reduced construction space and effective protection for wildlife animals. In spite of these advantages,…
Strong electromagnetic pulses (EMP) are generated from intense laser interactions with solid-density targets, and can be guided by the target geometry, specifically through conductive connections to the ground. We present an experimental…
A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half…
In the last decade, researchers have been investigating the severity of insulation breakdown caused by partial discharge (PD) in overhead transmission lines with covered conductors or electrical equipment such as generators and motors used…
Partial discharge (PD) incidents can occur in critical components of high-speed rail electric systems, such as transformers and switchgears, due to localized insulation defects that cannot withstand electric stress, leading to potential…
To ensure reliability, power transformers are monitored for partial discharge (PD) events, which are symptoms of transformer failure. Since failures can have catastrophic cascading consequences, it is critical to preempt them as early as…
Electric fields in a plasma that conducts a high-current pulse are measured as a function of time and space. The experiment is performed using a coaxial configuration, in which a current rising to 160 kA in 100 ns is conducted through a…
A novel methodology, named the diffusion profile method, is proposed in this research to measure the electric field of a low gain avalanche detector (LGAD).The proposed methodology utilizes the maximum of the time derivative of the edge…
A device and a method for producing ultrashort electron pulses with GHz repetition rates via pulsing an input direct current (dc) electron beam are provided. The device and the method are based on an electromagnetic-mechanical pulser (EMMP)…
Today,insulated overhead conductors are increasingly used in many places of the world due to the higher operational reliability, elimination of phase-to-phase contact, closer distances between phases and stronger protection for animals.…
Ultrashort, low-emittance electron pulses can be created at a high repetition rate by using a TM$_{110}$ deflection cavity to sweep a continuous beam across an aperture. These pulses can be used for time-resolved electron microscopy with…
After J. C. Maxwell brought forward the concept of displacement currents, H. R. Hertz and other scholars verified the existence of electromagnetic waves in experimental, and then confirmed indirectly the conceptive correctness of…
Dielectric barrier discharge (DBD) in air is characterized applying current measurement, numerical simulation and optical emission spectroscopy (OES). For OES, a non-calibrated spectrometer is used. This diagnostic method is applicable when…
This work discusses the suitability of typical power line communication (PLC) pulses for fault sensing in power lines via pulse-compression time-domain reflectometry (TDR). For this purpose, we first carefully outline a TDR system operating…
A two-core transducer assembly using a Fe73.5Nb3Cu1Si13.5B9 ribbon to detect a change of magnetic field is proposed and tested for displacement (linear and angular) and current sensor. Two identical inductors, with the ribbon as core, are a…
Undetected partial discharges (PDs) are a safety critical issue in high voltage (HV) gas insulated systems (GIS). While the diagnosis of PDs under AC voltage is well-established, the analysis of PDs under DC voltage remains an active…
A set of power supplies (PS) with output power rated from 100 W up to 10 kW for electromagnets powering was developed. These PS have range of current tuning of 60-80 db with high accuracy (error should be less than 0,01%). Some types of…
We present a novel microplasma flow reactor using a dielectric barrier discharge (DBD) driven by repetitively nanosecond high-voltage pulses. Our DBD-based geometry can generate a non-thermal plasma discharge at atmospheric pressure and…