相关论文: Synchronization Stability Analysis and Enhancement…
Small-signal instability of grid-connected power converters may arise when the converters use a phase-locked loop (PLL) to synchronize with a weak grid. Commonly, this stability problem (referred as PLL-synchronization stability in this…
In [1] a new adaptive phase-locked loop scheme for synchronization of a grid connected voltage source converter with guaranteed (almost) global stability properties was reported. To guarantee a suitable synchronization with the angle of the…
In this paper we are interested in the problem of adaptive synchronization of a voltage source converter with a possibly weak grid with unknown angle and frequency, but knowledge of its parameters. To guarantee a suitable synchronization…
The transient stability of traditional power systems is concerned with the ability of generators to stay synchronized with the positive-sequence voltage of the network, whether for symmetrical or asymmetrical faults. In contrast, both…
High penetration of distributed generators (DG) in modern power grids creates angle, voltage, and frequency instabilities. Most of the work in the literature has focused on small-signal stability analysis of single grid-connected inverters…
Fluctuations in phase angle and frequency under large disturbances can lead to loss of synchronism (LOS) in grid-following (GFL) converters. The power angle and frequency of synchronous generators (SGs) correspond to rotor position and…
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism…
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage…
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the…
The modern power grid features the high penetration of power converters, which widely employ a phase-locked loop (PLL) for grid synchronization. However, it has been pointed out that PLL can give rise to small-signal instabilities under…
This paper presents a novel strategy for the synchronization of grid-following Voltage Source Converters (VSCs) in power systems with low rotational inertia. The proposed synchronization unit is based on emulating the physical properties of…
Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations…
In recent years the need for DC distribution buses has increased considerably. As it can be noticed in the transport for example the distribution systems of the more electric aircrafts, ships, or electric cars. Given the complexities of the…
The power synchronization control (PSC) has been increasingly used with voltage-source converters (VSCs) connected to the weak ac grid. This paper presents an in-depth analysis on the transient stability of the PSC-VSC by means of the phase…
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage…
Large-scale integration of inverter-based resources into power grids worldwide is challenging their stability and security. This paper takes a closer look at synchronous condensers as a solution to mitigate stability challenges caused by…
Grid-synchronization stability (GSS) is an emerging stability issue of grid-tied voltage source converters (VSCs), which can be provoked by severe grid voltage sags. Although a qualitative understanding of the mechanism behind the loss of…
Small-signal synchronization instability (SSI) may be triggered when a grid-connected converter is operated in weak grids. This problem is highly related to the active and reactive power (referred to as complex power) generation or…
Grid-following inverters have been widely adopted as a grid interface for renewable energy, and ensuring their small-signal and large-signal stability is critical to modern power systems. Their large-signal, or transient, stability is a…
Modern power systems increasingly demand converter-driven generation systems that integrate seamlessly with grid infrastructure. Grid-based converters are particularly advantageous, as they operate in harmony with conventional synchronous…