相关论文: Performance comparison between signal digitizers a…
Sufficient current pulse information of nuclear radiation detectors can be retained by direct waveform digitization owing to the improvement of digitizer's performance. In many circumstances, reasonable cost and power consumption are on…
With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to…
To test and calibrate various detectors in nuclear and high energy physics experiments, a general purposed calibration instrument has been developed. All information including timing, amplitude and charge of signals can be directly obtained…
The demand from industry to produce accurate acceleration measurements down to ever lower frequencies and with ever lower noise is increasing. Different vibration transducers are used today for many different purposes within this area, like…
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…
We present the development and characterization of a generic, reconfigurable, low-cost ($<$ 350 USD) software-defined digital receiver system (DRS) for temporal correlation measurements in atomic spin ensembles. We demonstrate the use of…
Fast digitisers and digital pulse processing have been widely used for spectral application and pulse shape discrimination (PSD) owing to their advantages in terms of compactness, higher trigger rates, offline analysis, etc. Meanwhile, the…
Quantizers play a critical role in digital signal processing systems. Recent works have shown that the performance of quantization systems acquiring multiple analog signals using scalar analog-to-digital converters (ADCs) can be…
Analog-to-digital converters (ADCs) allow physical signals to be processed using digital hardware. Their conversion consists of two stages: Sampling, which maps a continuous-time signal into discrete-time, and quantization, i.e.,…
Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously…
In many physical experiments and applications with photomultiplier tubes (PMTs), high-speed pulse digitalization is used extensively. The current pulse from a PMT has a rising time of several to a hundred nanoseconds. The current pulse…
The analog signals generated in the read-out electronics of radiation detectors are shaped prior to the digitization in order to improve the signal to noise ratio (SNR). The real amplitude of the analog signal is then obtained using digital…
At present, fast waveform digitizing circuit is more and more employed in modern physics experiments for processing the signals from an array detector. A new fast waveform sampling digitizing circuit developed by us is presented in this…
NUMEXO2 is a 16 channels 14bit/200MHz digitizer and processing board initially developed for gamma-ray spectroscopy (for EXOGAM: EXOtic nuclei GAMma ray). Numexo2 has been gradually extended and improved as a general purpose digitizer to…
Front-end electronics equipped with high-speed digitizers are being used and proposed for future nuclear detectors. Recent literature reveals that deep learning models, especially one-dimensional convolutional neural networks, are promising…
Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically…
Analog signals processed in digital hardware are quantized into a discrete bit-constrained representation. Quantization is typically carried out using analog-to-digital converters (ADCs), operating in a serial scalar manner. In some…
A simplified digital spectrometer for the study of $\gamma$-rays with energies up to $\sim100$ MeV is presented and tested. The spectrometer is only consisted of a fast digital oscilloscope and three scintillation detectors which can work…
Electrocardiograms (ECGs) are essential for diagnosing cardiac pathologies, yet traditional paper-based ECG storage poses significant challenges for automated analysis. This study introduces ECGtizer, an open-source, fully automated tool…
We report a mixed-signal data acquisition (DAQ) system for optically detected magnetic resonance (ODMR) of solid-state spins. This system is designed and implemented based on a Field-Programmable-Gate-Array (FPGA) chip assisted with…