相关论文: First Penning trap mass measurement of $^{36}$Ca
Mass measurements on radionuclides along the potassium isotope chain have been performed with the ISOLTRAP Penning trap mass spectrometer. For 35K T1/2=178ms) to 46K (T1/2=105s) relative mass uncertainties of 2x10-8 and better have been…
Accurate mass determination of short-lived nuclides by Penning-trap spectrometers and progress in the spectroscopy of proton-rich nuclei have triggered renewed interest in the isobaric multiplet mass equation (IMME). The energy levels of…
The observed mass excesses of analog nuclear states with the same mass number $A$ and isospin $T$ can be used to test the isobaric multiplet mass equation (IMME), which has, in most cases, been validated to a high degree of precision. A…
The Isobaric Multiplet Mass Equation (IMME) has been successful at predicting the masses of isobaric analogue states in the same multiplet, while its coefficients are known to follow trends as functions of mass number. The Atomic Mass…
If the mass excess of neutron-deficient nuclei and their neutron-rich mirror partners are both known, it can be shown that deviations of the Isobaric Mass Multiplet Equation (IMME) in the form of a cubic term can be probed. Such a cubic…
Recent high-precision mass measurements of $^{9}$Li and $^{9}$Be, performed with the TITAN Penning trap at the TRIUMF ISAC facility, are analyzed in light of state-of-the-art shell model calculations. We find an explanation for the…
Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in $rp$ process reaction rates,…
The isobaric multiplet mass equation (IMME) is known to break down in the first T = 2, A = 32 isospin quintet. In this work we combine high-resolution experimental data with state-of-the-art shell-model calculations to investigate isospin…
Isobaric multiplets can be used to provide reliable mass predictions through the Isobaric Multiplet Mass Equation (IMME). Isobaric analogue states (IAS) for isospin multiplets from $T=1/2$ to $T=3$ have been studied within the 2012 Atomic…
The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving…
The Wigner Isobaric Multiplet Mass Equation (IMME) is the most fundamental prediction in nuclear physics with the concept of isospin. However, it was deduced based on the Wigner-Eckart theorem with the assumption that all charge-violating…
Masses of $^{52}$Co, $^{52}$Co$^m$, $^{52}$Fe, $^{52}$Fe$^m$, and $^{52}$Mn have been measured with the JYFLTRAP double Penning trap mass spectrometer. Of these, $^{52}$Co and $^{52}$Co$^m$ have been experimentally determined for the first…
Using the Penning trap mass spectrometer TITAN, we performed the first direct mass measurements of 20,21Mg, isotopes that are the most proton-rich members of the A = 20 and A = 21 isospin multiplets. These measurements were possible through…
A direct $Q_{EC}$-value measurement of the superallowed $\beta^+$ emitter $^{22}$Mg was performed using TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The direct ground-state to ground-state atomic mass difference between…
Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique.…
We present Penning-trap mass measurements of neutron-rich 44,47-50K and 49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass measurement was performed with a charge-bred 4+ ion utilizing the TITAN EBIT, and agrees…
Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental…
We report precision mass measurements of $^{133}$Sb, $^{133g,m}$Te, and $^{133g,m}$I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an…
We extend the nuclear Density Functional Theory (DFT) by including proton-neutron mixing and contact isospin-symmetry-breaking (ISB) terms up to next-to-leading order (NLO). Within this formalism, we perform systematic study of the nuclear…
The masses of $^{84}$Br, $^{105}$Mo, $^{115,119,121}$Pd, $^{122}$Ag, $^{127,129}$In, $^{132}$Sb and their respective isomeric states have been measured with the JYFLTRAP Penning trap mass spectrometer using the phase-imaging…