中文
相关论文

相关论文: Development of a Negative Ion Micro TPC Detector w…

200 篇论文

Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This…

Studies of micro time projection chambers using negative ion gas (NI$\mu$TPC) are conducted especially for direction-sensitive dark matter searches. A NI$\mu$TPC enables to measure the absolute position in the drift direction for…

Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark…

仪器与探测器 · 物理学 2020-08-26 Hirohisa Ishiura , Rob Veenhof , Kentaro Miuchi , Ikeda Tomonori

Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas…

仪器与探测器 · 物理学 2026-02-16 A. G. McLean , S. Higashino , R. R. Marcelo Gregorio , K. Miuchi , N. J. C. Spooner

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds.…

Directional methods have been considered to provide a solid proof for the direct detection of the dark matter. Gaseous time-projection-chambers (TPCs) are the most mature devices for directional dark matter searches although there still…

高能物理 - 实验 · 物理学 2024-03-08 Kentaro Miuchi

The three-dimensional (3-D) reconstruction of nuclear recoils is of interest for directional detection of fast neutrons and for direction-sensitive searches for weakly interacting massive particles(WIMPs), which may constitute the Dark…

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…

Gas-filled Time Projection Chambers (TPCs) with Gas Electron Multipliers (GEMs) and pixels appear suitable for direction-sensitive WIMP dark matter searches. We present the background and motivation for our work on this technology, past and…

天体物理仪器与方法 · 物理学 2015-05-30 S. E. Vahsen , H. Feng , M. Garcia-Sciveres , I. Jaegle , J. Kadyk , Y. Nguyen , M. Rosen , S. Ross , T. Thorpe , J. Yamaoka

The DMTPC directional dark matter detection experiment is a low-pressure CF4 gas time projection chamber, instrumented with charge and scintillation photon readout. This detector design strategy emphasizes reconstruction of WIMP-induced…

仪器与探测器 · 物理学 2019-08-13 Jocelyn Monroe

We report on the recent development of a versatile analog front-end compatible with a negative-ion $\mu$-TPC for a directional dark matter search as well as a dual-phase, next-generation $\mathcal{O}$(10~kt) liquid argon TPC to study…

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future…

Directional detection can provide unambiguous observation of Dark Matter interactions even in presence of insidious backgrounds. The DM-TPC collaboration is developing a detector with the goal of measuring the direction and sense of nuclear…

The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this…

The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…

仪器与探测器 · 物理学 2024-07-19 N. S. Phan , R. J. Lauer , E. R. Lee , D. Loomba , J. A. J. Matthews , E. H. Miller

NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of…

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of…

MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the…

天体物理仪器与方法 · 物理学 2009-06-01 C. Grignon , J. Billard , G. Bosson , O. Bourrion , O. Guillaudin , C. Koumeir , F. Mayet , D. Santos , P. Colas , E. Ferrer , I. Giomataris

At present time Budker INP is developing a Super Charm-Tau factory project, which consists of a high-luminosity collider with the luminosity of $10^{35}$,cm$^{-2}$s$^{-1}$ and a universal magnetic detector. The tracking system of the…

仪器与探测器 · 物理学 2020-08-26 V. K. Vadakeppattu , A. V. Sokolov , L. I. Shekhtman , T. V. Maltsev
‹ 上一页 1 2 3 10 下一页 ›