相关论文: Calibration of a Shower Lead-Scintillation Spectro…
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to…
An alternative parametrization of the particle shower longitudinal profile is presented. The accuracy of the obtained shower profile description is about 2-3% for the 0-1500 g/cm^2 atmosphere slant depths and primary H, He,... Fe nuclei in…
The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh…
Recent applications of cosmic-ray muons require accurate modeling of their flux at low-energy. However, no measurement has been reported below 400 MeV. Therefore, we developed a full-absorption muon energy spectrometer to obtain energy…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…
A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by…
Measuring the angles of muons and electrons in air showers is proposed as a method for studying the primary cosmic-ray mass composition near the knee of the cosmic-ray energy spectrum at a few $10^{15}$ eV. Conventional tracking detectors…
A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in…
Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…
The SoLid experiment aims to make a measurement of very short distance neutrino oscillations using reactor antineutrinos. Key to its sensitivity are the experiments high spatial and energy resolution, combined with a very suitable reactor…
The recent observations of muon charge ratio up to about 10 TeV and of atmospheric neutrinos up to energies of about 400 TeV has triggered a renewed interest into the high-energy interaction models and cosmic ray primary composition. A…
Scintillation detectors are essential tools for radiation measurement, but calibrating them accurately can be challenging, especially when full-energy peaks are not prominent. This is common in detectors like plastic scintillators. Current…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…
Cosmogenic muon-induced radioactive isotopes pose a significant background source for deep-underground low-background experiments. Although rock overburdens at underground sites substantially attenuate the cosmogenic muon flux, residual…
The lateral and longitudinal profiles of the hadronic showers detected by iron-scintillator tile hadron calorimeter with longitudinal tile configuration have been investigated. The results are based on 100 GeV pion beam data. Due to the…
The Collider Detector at Fermilab (CDF) is a general-purpose experimental apparatus with an inner tracking detector for measuring charged particles, surrounded by a calorimeter for measurements of electromagnetic and hadronic showers. We…
This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle…
Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…