中文
相关论文

相关论文: Gel phantom data for dynamic X-ray tomography

200 篇论文

This is the documentation for Spatio-TEmporal Motor-POwered (STEMPO) phantom for dynamic X-ray tomography. Provided are different measurements designed for testing dynamic tomography reconstruction algorithms. The measured data and…

图像与视频处理 · 电气工程与系统科学 2025-08-05 Tommi Heikkilä

This is the documentation of the tomographic X-ray data of cross phantom made available at this https URL The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The…

医学物理 · 物理学 2018-09-05 Salla Latva-Äijö , Alexander Meaney , Samuli Siltanen

This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to…

医学物理 · 物理学 2018-02-27 Alexander Meaney , Zenith Purisha , Samuli Siltanen

Purpose: To develop and validate a phantom for diagnostic ultrasound (US) scanners by embedding targets in gel wax to determine the image uniformity, lateral and axial resolution, and diameter of a stainless-steel disc. Materials and…

This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in…

This is the documentation of the tomographic X-ray data of a walnut made available at http://www.fips.fi/dataset.php . The data can be freely used for scientific purposes with appropriate references to the data and to this document in…

数据分析、统计与概率 · 物理学 2015-02-16 Keijo Hämäläinen , Lauri Harhanen , Aki Kallonen , Antti Kujanpää , Esa Niemi , Samuli Siltanen

This is the documentation of the tomographic X-ray data of a lotus root, filled with four different attenuating objects, of different sizes. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with…

数据分析、统计与概率 · 物理学 2016-10-14 Tatiana A. Bubba , Andreas Hauptmann , Simo Huotari , Juho Rimpeläinen , Samuli Siltanen

This is the documentation of Computed Tomography (CT) data of a pen-spring. The open data set is available at https://zenodo.org/record/3266936#.XRyMdCZS9oA and can be freely used for scientific purposes with appropriate references to the…

医学物理 · 物理学 2019-07-04 Juliaana Juurakko , Zenith Purisha , Simo Särkkä

We describe a method aiming at increasing the dynamic range of X-ray detectors. Two X-ray exposures of an object are acquired at different dose levels and constitute the only input data. The values of the parameters which are needed to…

医学物理 · 物理学 2007-05-23 Evangelos Matsinos , Wolfgang Kaissl

We present an experimental setup and methodology designed to facilitate high-precision thermal measurements required for infrared medical tomography. The approach which is best suited for the study of specialized hardware phantoms comprises…

医学物理 · 物理学 2026-04-08 Anna Frixou , Efstathios Stiliaris , Costas N. Papanicolas

We report the first experimental test of an analytic image reconstruction algorithm for optical tomography with large data sets. Using a continuous-wave optical tomography system with 10^8 source-detector pairs, we demonstrate the…

医学物理 · 物理学 2007-05-23 Zheng-Min Wang , George Y. Panasyuk , Vadim A. Markel , John C. Schotland

Modern Flash X-ray diffraction Imaging (FXI) acquires diffraction signals from single biomolecules at a high repetition rate from X-ray Free Electron Lasers (XFELs), easily obtaining millions of 2D diffraction patterns from a single…

图像与视频处理 · 电气工程与系统科学 2020-10-28 Jing Liu , Stefan Engblom , Carl Nettelblad

Cryosurgery employs a safe and relatively simple technique of exposure and is an advantageous and highly rated method. For its effective application, it is necessary to control both the volume of the expanding freezing zone and volumetric…

Purpose: Digital phantoms are one of the key components of virtual imaging trials (VITs) that aim to assess and optimize new medical imaging systems and algorithms. However, these phantoms vary in their voxel resolution, appearance, and…

医学物理 · 物理学 2024-02-02 Amar Kavuri , Mini Das

The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets…

X-ray microtomography is a versatile tool allowing the measurement of the 3D structure of optically thick samples. As a non-destructive technique, it is readily adapted to 4D imaging, where a sample can be monitored over time, and…

仪器与探测器 · 物理学 2025-12-17 Harry Allan , Tom Partridge , Joseph Jacob , Marco Endrizzi

We study a microscopically realistic model of a physical gel and use computer simulations to investigate its static and dynamic properties at thermal equilibrium. The phase diagram comprises a sol phase, a coexistence region ending at a…

软凝聚态物质 · 物理学 2009-11-13 Pablo I. Hurtado , Pinaki Chaudhuri , Ludovic Berthier , Walter Kob

High resolution low angle x-ray data are reported for the gel phase of DPPC lipid bilayers, extending the previous q range of 1.0 {\AA}-1 to 1.3 {\AA}-1, and employing a new technique to obtain more accurate intensities and form factors…

生物物理 · 物理学 2019-03-27 John F Nagle , Pierre Cognet , Fernando G. Dupuy , Stephanie Tristram-Nagle

This is the documentation of the 3D dynamic tomographic X-ray (CT) data of a ladybug. The open data set is available https://zenodo.org/record/3375488#.XV_T3vxS9oA and can be freely used for scientific purposes with appropriate references…

医学物理 · 物理学 2019-08-26 Juliaana Juurakko , Zenith Purisha , Simo Särkkä

X-ray CT dose measurement has mainly been performed using an ionization chamber dosimeter. Therefore, the dose distribution has not been sufficiently studied. We investigated the importance of evaluating the two or three-dimensional dose…

‹ 上一页 1 2 3 10 下一页 ›