中文
相关论文

相关论文: A transportable interrogation laser system with an…

200 篇论文

We present a transportable ultra-stable clock laser system based on a Fabry-P\'erot cavity with crystalline Al$_{0.92}$Ga$_{0.08}$As/GaAs mirror coatings, fused silica (FS) mirror substrates and a 20~cm-long ultra-low expansion…

We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser…

原子物理 · 物理学 2015-06-22 N. Poli , M. Schioppo , S. Vogt , St. Falke , U. Sterr , Ch. Lisdat , G. M. Tino

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400…

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if…

原子物理 · 物理学 2016-01-20 Ali Al-Masoudi , Sören Dörscher , Sebastian Häfner , Uwe Sterr , Christian Lisdat

We describe a transportable optical lattice clock based on the $^1\mathrm{S}_0 \rightarrow {^3\mathrm{P}_0}$ transition of lattice-trapped $^{87}$Sr atoms with a total systematic uncertainty of $2.1 \times 10^{-18}$. The blackbody radiation…

原子物理 · 物理学 2025-07-21 I. Nosske , C. Vishwakarma , T. Lücke , J. Rahm , N. Poudel , S. Weyers , E. Benkler , S. Dörscher , C. Lisdat

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to…

We describe a frequency stabilized diode laser at 698 nm used for high resolution spectroscopy of the 1S0-3P0 strontium clock transition. For the laser stabilization we use state-of-the-art symmetrically suspended optical cavities optimized…

原子物理 · 物理学 2011-01-13 Marco. G. Tarallo , Nicola Poli , Marco Schioppo , Guglielmo M. Tino

Optical clocks require an ultra-stable laser to probe and precisely measure the frequency of the narrow-linewidth clock transition. We introduce a portable ultraviolet (UV) laser system for use in an aluminum quantum logic clock,…

The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidth. We present two ultrastable laser systems based on 48 cm long Fabry-Perot cavities made of ULE glass in horizontal and…

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a…

We present the design and realization of two reference cavities for ultra-stable lasers addressing narrow transitions in mixed-species (In+ / Yb+) Coulomb crystals. With a simple setup, we achieve a fractional frequency instability close to…

Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and…

The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency.…

原子物理 · 物理学 2015-05-20 Y. Y. Jiang , A. D. Ludlow , N. D. Lemke , R. W. Fox , J. A. Sherman , L. -S. Ma , C. W. Oates

We report on the setup and characterization of a 698 nm master-slave diode laser system to probe the 1S0-3P0 clock transition of strontium atoms confined in a one-dimensional optical lattice. A linewidth in the order of around 100 Hz of the…

Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to…

We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-P\'erot cavity…

原子物理 · 物理学 2015-03-13 S. T. Dawkins , R. Chicireanu , M. Petersen , J. Millo , D. V. Magalhães , C. Mandache , Y. Le Coq , S. Bize

The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the…

光学 · 物理学 2015-05-14 Didier Guyomarc'H , Gaëtan Hagel , Cédric Zumsteg , Martina Knoop

We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are…

原子物理 · 物理学 2022-04-29 Matteo Barbiero , Davide Calonico , Filippo Levi , Marco G. Tarallo

We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$…

We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of…

‹ 上一页 1 2 3 10 下一页 ›