相关论文: A High Count-Rate and Depth-of-Interaction Resolvi…
Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…
The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…
Positron Emission Tomography (PET) is a Nuclear Medicine technique that creates images that allow the study of metabolic activity and organ function using radiopharmaceuticals. Continuous improvement of scintillation detectors for radiation…
New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating…
Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…
A systematic study is conducted to understand the coincident resolving time (CRT) for a pair of Lutetium-yttrium oxyorthosilicate (LYSO) and the plastic scintillation detector bars under the Geant4 framework. Crystals are coupled to a…
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic…
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…
We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…
Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40…
We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved…
Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This work presents a fabrication method based on additive…