中文
相关论文

相关论文: Fast LLMMSE filter for low-dose CT imaging

200 篇论文

Sparse-view Computed Tomography (CT) is an emerging protocol designed to reduce X-ray dose radiation in medical imaging. Traditional Filtered Back Projection algorithm reconstructions suffer from severe artifacts due to sparse data. In…

数值分析 · 数学 2024-12-03 Elena Loli Piccolomini , Davide Evangelista , Elena Morotti

Score-based diffusion models have significantly advanced generative deep learning for image processing. Measurement conditioned models have also been applied to inverse problems such as CT reconstruction. However, the conventional approach,…

医学物理 · 物理学 2025-02-24 Matthew Tivnan , Dufan Wu , Quanzheng Li

Traditional model-based image reconstruction (MBIR) methods combine forward and noise models with simple object priors. Recent application of deep learning methods for image reconstruction provides a successful data-driven approach to…

图像与视频处理 · 电气工程与系统科学 2022-05-20 Ling Chen , Zhishen Huang , Yong Long , Saiprasad Ravishankar

We propose a Noise Entangled GAN (NE-GAN) for simulating low-dose computed tomography (CT) images from a higher dose CT image. First, we present two schemes to generate a clean CT image and a noise image from the high-dose CT image. Then,…

图像与视频处理 · 电气工程与系统科学 2021-02-22 Chuang Niu , Ge Wang , Pingkun Yan , Juergen Hahn , Youfang Lai , Xun Jia , Arjun Krishna , Klaus Mueller , Andreu Badal , KyleJ. Myers , Rongping Zeng

Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current…

计算机视觉与模式识别 · 计算机科学 2019-03-06 Xin Yi , Paul Babyn

The use of brain images as markers for diseases or behavioral differences is challenged by the small effects size and the ensuing lack of power, an issue that has incited researchers to rely more systematically on large cohorts. Coupled…

机器学习 · 统计学 2015-11-17 Bertrand Thirion , Andrés Hoyos-Idrobo , Jonas Kahn , Gael Varoquaux

X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the…

数值分析 · 数学 2016-02-24 Jae Kyu Choi , Bin Dong , Xiaoqun Zhang

Spectral computed tomography (CT) has a great superiority in lesion detection, tissue characterization and material decomposition. To further extend its potential clinical applications, in this work, we propose an improved tensor dictionary…

计算机视觉与模式识别 · 计算机科学 2018-07-25 Weiwen Wu , Yanbo Zhang , Qian Wang , Fenglin Liu , Peijun Chen , Hengyong Yu

Due to the potential risk of inducing cancers, radiation dose of X-ray CT should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts usually occur due to photon starvation, beamhardening, etc, which…

计算机视觉与模式识别 · 计算机科学 2018-02-07 Eunhee Kang , Junhong Min , Jong Chul Ye

Four-dimensional computed tomography (4DCT) has been widely used in cancer radiotherapy for accurate target delineation and motion measurement for tumors in thorax and upper abdomen areas. However, 4DCT simulation is associated with much…

医学物理 · 物理学 2015-05-19 Zhen Tian , Xun Jia , Steve B. Jiang

Image denoising is a prerequisite for downstream tasks in many fields. Low-dose and photon-counting computed tomography (CT) denoising can optimize diagnostic performance at minimized radiation dose. Supervised deep denoising methods are…

机器学习 · 计算机科学 2022-01-06 Chuang Niu , Mengzhou Li , Fenglei Fan , Weiwen Wu , Xiaodong Guo , Qing Lyu , Ge Wang

Computed Tomography (CT) imposes risk on the patients due to its inherent X-ray radiation, stimulating the development of low-dose CT (LDCT) imaging methods. Lowering the radiation dose reduces the health risks but leads to noisier…

图像与视频处理 · 电气工程与系统科学 2022-11-03 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Nonnegative matrix factorization (NMF) has become a ubiquitous tool for data analysis. An important variant is the sparse NMF problem which arises when we explicitly require the learnt features to be sparse. A natural measure of sparsity is…

Denoising low-dose computed tomography (CT) images is a critical task in medical image computing. Supervised deep learning-based approaches have made significant advancements in this area in recent years. However, these methods typically…

图像与视频处理 · 电气工程与系统科学 2023-07-17 Xuan Liu , Yaoqin Xie , Jun Cheng , Songhui Diao , Shan Tan , Xiaokun Liang

Abstract Objective. Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of…

信号处理 · 电气工程与系统科学 2024-11-15 Louise Friot-Giroux , Françoise Peyrin , Voichita Maxim

This work explores the scope of Frequent Sequence Mining in the domain of Lossy Image Compression. The proposed work is based on the idea of clustering pixels and using the cluster identifiers in the compression. The DCT phase in JPEG is…

图像与视频处理 · 电气工程与系统科学 2026-01-28 Avinash Kadimisetty , Oswald C , Sivaselvan B , Alekhya Kadimisetty

We set out to simulate four reduced dose-levels (60%-dose, 40%-dose, 20%-dose, and 10%-dose) of standard CT imaging using Beer-Lambert's law across 49 patients infected with COVID-19. Then, three denoising filters, namely Gaussian,…

Deep learning is a very promising technique for low-dose computed tomography (LDCT) image denoising. However, traditional deep learning methods require paired noisy and clean datasets, which are often difficult to obtain. This paper…

图像与视频处理 · 电气工程与系统科学 2023-08-15 Yuting Zhu , Qiang He , Yudong Yao , Yueyang Teng

Low-dose CT (LDCT) imaging attracted a considerable interest for the reduction of the object's exposure to X-ray radiation. In recent years, supervised deep learning (DL) has been extensively studied for LDCT image reconstruction, which…

图像与视频处理 · 电气工程与系统科学 2022-10-06 Qiaoqiao Ding , Hui Ji , Yuhui Quan , Xiaoqun Zhang

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

医学物理 · 物理学 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang