相关论文: Ultra-sensitive SQUID instrumentation for MEG and …
Superconducting QUantum-Interference Devices (SQUIDs) make magnetic resonance imaging (MRI) possible in ultra-low microtesla-range magnetic fields. In this work, we investigate the design parameters affecting the signal and noise…
The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We…
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and…
SQUID systems for ultra-low-field magnetic resonance (ULF MR) feature superconducting pick-up coils which must tolerate exposure to pulsed fields of up to 100 mT. Using type-II superconductor niobium (Nb) field distortions due to trapped…
We report on the development of an ultralow noise thin-film based SQUID magnetometer. A niobium thin-film pickup coil is connected to the input coil of a SQUID current sensor. The low capacitance of the used sub-micrometer cross-type…
Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique…
We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The…
Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of…
Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement…
We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a…
In this paper we discuss design concepts for increasing the spatial resolution, improving the sensitivity, and reducing the invasiveness in scanning Superconducting Quantum Interference Device (SQUID) microscope sensors with integrated flux…
Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the…
Due to their superior noise performance, SQUIDs are an attractive alternative to high electron mobility transistors for constructing ultra-low-noise microwave amplifiers for cryogenic use. We describe the use of a lumped element SQUID…
Superconducting Quantum Interference Devices (SQUIDs) are one of the most popular devices in superconducting electronics. They combine the Josephson effect with the quantization of magnetic flux in superconductors. This gives rise to one of…
The superconducting quantum interference device (SQUID) magnetometer is one of the most sensitive experimental techniques to magnetically characterize samples with high sensitivity. Here we present a detailed discussion of possible…
The magnetic sensing at nanoscale level is a promising and interesting research topic of nanoscience. Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems. The study of small spin cluster, like…
We investigate rf SQUIDs (Superconducting QUantum Interference Devices), coupled to a resonant input circuit, a readout tank circuit and a preamplifier, by numerically solving the corresponding Langevin equations and optimizing model…
Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…
Single-channel SQUID system technology, operating at a noise level of 100s of aT/$\sqrt{\textrm{Hz}}$, enables the non-invasive detection of synchronized spiking activity at the single-trial level via magnetoencephalography (MEG). However,…
Superconducting quantum interference devices (SQUIDs) that incorporate two superconductor/insulator/superconductor (SIS) Josephson junctions in a closed loop form the core of some of the most sensitive detectors of magnetic and electric…