Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose.…
Purpose: HDR brachytherapy is a widely adopted modality for cancer treatment. However, it is not free from error and uncertainty. In-vivo dosimetry (IVD) is the only technique that can confirm correct dose delivery. This study details and…
Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the…
Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose…
Purpose: We introduce a novel concept of a compact multiprobe scintillator detector and demonstrate its applicability in HDR-brachytherapy. Our fabricated seven-probe system is sufficiently narrow to be inserted in a brachytherapy needle or…
Introduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the…
Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry. Methods: Dose linearity, mean dose rate, and…
Purpose: For more than a decade that plastic optical fiber based dosimeters have been developed for medical applications. The feasibility of dosimeters using optical fibers that are almost Cherenkov light free has been demonstrated in some…
Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging…
Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates ($\bar{DR}$) above 100 Gy/s and doses per pulse ($D_p$) exceeding 1.5…
The increasing interest in FLASH-RT has lead to the conversion of linear accelerators to enable ultra-high dose rate (UHDR) beams for preclinical research. Dosimetry hereof remains challenging with several crucial aspects missing. This work…
This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized…
Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core…
FLASH-RT has proven beneficial in preclinical studies. However, the lack of accurate real time 2D dosimetry is a limiting factor. In this work, an innovative solution for 2D real time dosimetry in UHDR electron beams is presented. The…
This study presents the development and validation of an independent software tool based on the Varian Eclipse Scripting API (ESAPI) for multi-modal brachytherapy Quality Assurance (QA). The tool addresses GEC-ESTRO HDR protocols and LDR…
We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry…
Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…
Background: In vivo dosimetry is essential for treatment verification in modern radiotherapy, but existing techniques are limited by spatiotemporal resolution and performance on non-uniform anatomy. Scintillation imaging dosimetry shows…