Attenuation correction is an essential requirement of positron emission tomography (PET) image reconstruction to allow for accurate quantification. However, attenuation correction is particularly challenging for PET-MRI as neither PET nor…

Recently, more and more attention is drawn to the field of medical image synthesis across modalities. Among them, the synthesis of computed tomography (CT) image from T1-weighted magnetic resonance (MR) image is of great importance,…

计算机视觉与模式识别 · 计算机科学 2017-11-10 Lei Xiang , Qian Wang , Xiyao Jin , Dong Nie , Yu Qiao , Dinggang Shen

Computed tomography (CT) is a widely used imaging modality for medical diagnosis and treatment. In electroencephalography (EEG), CT imaging is necessary for co-registering with magnetic resonance imaging (MRI) and for creating more accurate…

医学物理 · 物理学 2019-06-12 Andreas D. Lauritzen , Xenophon Papademetris , Sergei Turovets , John A. Onofrey

The ability to synthesise Computed Tomography images - commonly known as pseudo CT, or pCT - from MRI input data is commonly assessed using an intensity-wise similarity, such as an L2-norm between the ground truth CT and the pCT. However,…

Positron Emission Tomography (PET) imaging requires accurate attenuation correction (AC) to account for photon loss due to tissue density variations. In PET/MR systems, computed tomography (CT), which offers a straightforward estimation of…

图像与视频处理 · 电气工程与系统科学 2025-04-11 Weijie Chen , James Wang , Alan McMillan

Deep learning techniques, particularly convolutional neural networks (CNNs), have gained traction for synthetic computed tomography (sCT) generation from Magnetic resonance imaging (MRI), Cone-beam computed tomography (CBCT) and PET. In…

图像与视频处理 · 电气工程与系统科学 2023-08-29 Satoshi Kondo , Satoshi Kasai , Kousuke Hirasawa

Positron emission tomography (PET) suffers from severe resolution limitations which limit its quantitative accuracy. In this paper, we present a super-resolution (SR) imaging technique for PET based on convolutional neural networks (CNNs).…

图像与视频处理 · 电气工程与系统科学 2021-07-29 Tzu-An Song , Samadrita Roy Chowdhury , Fan Yang , Joyita Dutta

This paper strives to generate a synthetic computed tomography (CT) image from a magnetic resonance (MR) image. The synthetic CT image is valuable for radiotherapy planning when only an MR image is available. Recent approaches have made…

图像与视频处理 · 电气工程与系统科学 2021-07-20 Zenglin Shi , Pascal Mettes , Guoyan Zheng , Cees Snoek

Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull…

Model-based treatment planning for transcranial ultrasound therapy typically involves mapping the acoustic properties of the skull from an x-ray computed tomography (CT) image of the head. Here, three methods for generating pseudo-CT images…

MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between…

计算机视觉与模式识别 · 计算机科学 2017-08-04 Jelmer M. Wolterink , Anna M. Dinkla , Mark H. F. Savenije , Peter R. Seevinck , Cornelis A. T. van den Berg , Ivana Isgum

The analysis of multi-modality positron emission tomography and computed tomography (PET-CT) images for computer aided diagnosis applications requires combining the sensitivity of PET to detect abnormal regions with anatomical localization…

计算机视觉与模式识别 · 计算机科学 2019-10-29 Ashnil Kumar , Michael Fulham , Dagan Feng , Jinman Kim

Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR…

医学物理 · 物理学 2018-08-01 Kuang Gong , Jaewon Yang , Kyungsang Kim , Georges El Fakhri , Youngho Seo , Quanzheng Li

Deep-learning-based MR-to-CT synthesis can estimate the electron density of tissues, thereby facilitating PET attenuation correction in whole-body PET/MR imaging. However, whole-body MR-to-CT synthesis faces several challenges including the…

图像与视频处理 · 电气工程与系统科学 2024-11-27 Jiaxu Zheng , Zhenrong Shen , Lichi Zhang , Qun Chen

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

计算机视觉与模式识别 · 计算机科学 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

Computed tomography (CT) is widely used in screening, diagnosis, and image-guided therapy for both clinical and research purposes. Since CT involves ionizing radiation, an overarching thrust of related technical research is development of…

图像与视频处理 · 电气工程与系统科学 2019-06-25 Chenyu You , Guang Li , Yi Zhang , Xiaoliu Zhang , Hongming Shan , Shenghong Ju , Zhen Zhao , Zhuiyang Zhang , Wenxiang Cong , Michael W. Vannier , Punam K. Saha , Ge Wang

Image segmentation, real-value prediction, and cross-modal translation are critical challenges in medical imaging. In this study, we propose a versatile multi-task neural network framework, based on an enhanced Transformer U-Net…

图像与视频处理 · 电气工程与系统科学 2023-12-19 Zhuoyao Xin , Christopher Wu , Dong Liu , Chunming Gu , Jia Guo , Jun Hua

The cost-effectiveness and practical harmlessness of ultrasound imaging have made it one of the most widespread tools for medical diagnosis. Unfortunately, the beam-forming based image formation produces granular speckle noise, blurring,…

计算机视觉与模式识别 · 计算机科学 2017-10-19 Sanketh Vedula , Ortal Senouf , Alex M. Bronstein , Oleg V. Michailovich , Michael Zibulevsky

Increasing use of CT in modern medical practice has raised concerns over associated radiation dose. Reduction of radiation dose associated with CT can increase noise and artifacts, which can adversely affect diagnostic confidence. Denoising…

计算机视觉与模式识别 · 计算机科学 2017-02-24 Qingsong Yang , Pingkun Yan , Mannudeep K. Kalra , Ge Wang

Attenuation correction (AC) is essential for the generation of artifact-free and quantitatively accurate positron emission tomography (PET) images. However, AC of PET faces challenges including inter-scan motion and erroneous transformation…

图像与视频处理 · 电气工程与系统科学 2023-10-04 Yu Guan , Bohui Shen , Xinchong Shi , Xiangsong Zhang , Bingxuan Li , Qiegen Liu