相关论文: The Muon $(g-2)$ Spin Equations, the Magic $\gamma…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $\omega_a^m$ are associated with…
The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon $(g-2)$ experiment, E821, at the Brookhaven AGS has the goal to measure the muon anomalous magnetic moment to a relative accuracy of $\pm 3.5 \times 10^{-7}$. A superferric 14 m diameter storage ring has been constructed and an…
We calculate the corrections for constant radial magnetic field in muon g--2 and electric-dipole-moment experiments in storage rings. While the correction is negligible for the current generation of g--2 experiments, it affects the upcoming…
The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more…
The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released…
The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at…
We present the concept of a compact storage ring of less than 0.5 m orbit radius to search for the electric dipole moment of the muon ($d_\mu$) by adapting the "frozen spin" method. At existing muon facilities a statistics limited…
A new superferric magnetic storage ring with highly homogeneous field at 1.45 T and weak electrostatic focussing is described which has been set up at the Brookhaven National Laboratory (BNL), USA, for a precision measurement of the…
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…
If the technology for muon storage rings one day permits sensitivity to precession at the order of $10^{-8}$ Hz, the local gravitational field of Earth can be a dominant contribution to the precession of the muon, which, if ignored, can…
We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
The Fermi National Accelerator Laboratory (FNAL) Muon $g-2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…