中文
相关论文

相关论文: Calibration of a two-phase xenon time projection c…

200 篇论文

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at…

仪器与探测器 · 物理学 2023-07-12 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , B. Andrieu , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , T. K. Bui , C. Cai , C. Capelli , J. M. R. Cardoso , D. Cichon , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , S. Diglio , K. Eitel , A. Elykov , S. Farrell , A. D. Ferella , C. Ferrari , H. Fischer , W. Fulgione , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , M. Guida , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , J. Howlett , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , A. Joy , N. Kato , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , J. Palacio , R. Peres , C. Peters , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , P. Sanchez-Lucas , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , T. Wolf , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , S. Zerbo , M. Zhong , T. Zhu , C. Geppert , J. Riemer

For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data…

天体物理仪器与方法 · 物理学 2021-11-02 L. Baudis , Y. Biondi , M. Galloway , F. Girard , S. Hochrein , S. Reichard , P. Sanchez-Lucas , K. Thieme , J. Wulf

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in…

A dual-phase xenon time-projection chamber was built at Nikhef in Amsterdam as a direct dark matter detection R&D facility. In this paper, the setup is presented and the first results from a calibration with a $^{22}$Na gamma-ray source are…

仪器与探测器 · 物理学 2016-11-23 E. Hogenbirk , J. Aalbers , M. Bader , P. A. Breur , A. Brown , M. P. Decowski , C. Tunnell , R. Walet , A. P. Colijn

We present measurements of light and charge signals in a dual-phase time projection chamber at electric fields varying from 10 V/cm up to 500 V/cm and at zero field using 511 keV gamma rays from a $^{22}$Na source. We determine the drift…

仪器与探测器 · 物理学 2018-11-01 E. Hogenbirk , M. P. Decowski , K. McEwan , A. P. Colijn

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization…

The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field…

天体物理仪器与方法 · 物理学 2017-11-22 L. W. Goetzke , E. Aprile , M. Anthony , G. Plante , M. Weber

We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the…

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the…

We report on the calibration of an argon/isobutane (97.7 %/2.3 %)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy…

仪器与探测器 · 物理学 2018-04-18 Christoph Krieger , Jochen Kaminski , Theodoros Vafeiadis , Klaus Desch

The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the…

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…

仪器与探测器 · 物理学 2026-05-01 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…

天体物理学 · 物理学 2008-11-26 T. Shutt , C. E. Dahl , J. Kwong , A. Bolozdynya , P. Brusov

Dual-phase liquid xenon (LXe) detectors lead the direct search for particle dark matter. Understanding the signal production process of nuclear recoils in LXe is essential for the interpretation of LXe based dark matter searches. Up to now,…

XeBRA is a flexible cryogenic platform designed to perform research and development for liquid xenon detectors searching for rare events. Its extra-large outer cryostat makes it possible to install a wide variety of detector designs. We…

Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure…

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…

仪器与探测器 · 物理学 2015-06-17 Qing Lin , Yuehuan Wei , Jie Bao , Jie Hu , Xinran Li , Wolfgang Lorenzon , Kaixuan Ni , Michael Schubnell , Mengjiao Xiao , Xiang Xiao

The ionization yield in the two-phase liquid xenon dark-matter detector has been studied in keV nuclear-recoil energy region. The newly-obtained nuclear quenching as well as the recently-measured average energy required to produce an…

仪器与探测器 · 物理学 2013-10-09 Wei Mu , Xiangdong Ji
‹ 上一页 1 2 3 10 下一页 ›