相关论文: An Open Source, FPGA-based LeKID readout for BLAST…
We describe possible applications of pixelized micro-well detectors (PMWDs) as three-dimensional charged particle trackers in advanced gamma-ray telescope concepts. A micro-well detector consists of an array of individual micro-patterned…
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028.…
We have assembled a tiled array (220 cm2) of fine pixel (0.6 mm) imaging CZT detectors for a balloon borne wide-field hard X-ray telescope, ProtoEXIST2. ProtoEXIST2 is a prototype experiment for a next generation hard X-ray imager MIRAX-HXI…
The POEMMA-Balloon with Radio (PBR) is a proposed payload to fly on a NASA Super Pressure Balloon (SPB). It will act as a pathfinder of the Probe Of Extreme Multi-Messenger Astrophysics (POEMMA) detector. PBR will consist of an innovative…
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging…
The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its…
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…
The time-of-flight Highly Granular Neutron Detector (HGND) with a multilayer longitudinal structure of interleaved absorber and scintillator plates, high transverse granularity and a time resolution of about 150 ps is currently under…
Many of the transformative processes in the Universe have taken place in regions obscured by dust, and are best studied with far-IR spectroscopy. We present the Cryogenic-Aperture Large Infrared-Submillimeter Telescope Observatory…
The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device…
The NeXT (New exploration X-ray Telescope), the new Japanese X-ray Astronomy Satellite following Suzaku, is an international X-ray mission which is currently planed for launch in 2013. NeXT is a combination of wide band X-ray spectroscopy…
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a…
Jet constituents provide a more detailed description of a jet's radiation pattern than global observables. In simulations for ATLAS Run-2 data (2015-2018), transformer-based taggers trained on low-level inputs outperformed traditional…
The Balloon-borne Large Aperture Submillimeter Telescope (BLAST) operated successfully during a 100-hour flight from northern Sweden in June 2005 (BLAST05). As part of the calibration and pointing procedures, several compact sources were…
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…
The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event…
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core…
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/\Delta…