中文
相关论文

相关论文: Low-Dose CT via Deep Neural Network

200 篇论文

To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method…

医学物理 · 物理学 2016-10-04 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang

Low-dose CT denoising is a challenging task that has been studied by many researchers. Some studies have used deep neural networks to improve the quality of low-dose CT images and achieved fruitful results. In this paper, we propose a deep…

图像与视频处理 · 电气工程与系统科学 2019-02-28 Maryam Gholizadeh-Ansari , Javad Alirezaie , Paul Babyn

Low dose CT is of great interest in these days. Dose reduction raises noise level in projections and decrease image quality in reconstructions. Model based image reconstruction can combine statistical noise model together with prior…

医学物理 · 物理学 2019-10-16 Kaichao Liang , Li Zhang , Yirong Yang , HongKai Yang , Yuxiang Xing

Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but…

图像与视频处理 · 电气工程与系统科学 2021-02-05 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

The application of ionizing radiation for diagnostic imaging is common around the globe. However, the process of imaging, itself, remains to be a relatively hazardous operation. Therefore, it is preferable to use as low a dose of ionizing…

图像与视频处理 · 电气工程与系统科学 2023-11-01 A. Demir , M. M. A. Shames , O. N. Gerek , S. Ergin , M. Fidan , M. Koc , M. B. Gulmezoglu , A. Barkana , C. Calisir

Computed tomography (CT) has played a vital role in medical diagnosis, assessment, and therapy planning, etc. In clinical practice, concerns about the increase of X-ray radiation exposure attract more and more attention. To lower the X-ray…

图像与视频处理 · 电气工程与系统科学 2022-01-19 Zhicheng Zhang , Xiaokun Liang , Wei Zhao , Lei Xing

Low Dose CT Denoising research aims to reduce the risks of radiation exposure to patients. Recently researchers have used deep learning to denoise low dose CT images with promising results. However, approaches that use mean-squared-error…

图像与视频处理 · 电气工程与系统科学 2024-09-05 Sepehr Ataei , Javad Alirezaie , Paul Babyn

A major challenge in computed tomography (CT) is how to minimize patient radiation exposure without compromising image quality and diagnostic performance. The use of deep convolutional (Conv) neural networks for noise reduction in Low-Dose…

计算机视觉与模式识别 · 计算机科学 2019-08-06 Chenyu You , Linfeng Yang , Yi Zhang , Ge Wang

Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current…

计算机视觉与模式识别 · 计算机科学 2019-03-06 Xin Yi , Paul Babyn

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

图像与视频处理 · 电气工程与系统科学 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

Despite the indispensable role of X-ray computed tomography (CT) in diagnostic medicine field, the associated ionizing radiation is still a major concern considering that it may cause genetic and cancerous diseases. Decreasing the exposure…

图像与视频处理 · 电气工程与系统科学 2021-06-09 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

The acquisition conditions for low-dose and high-dose CT images are usually different, so that the shifts in the CT numbers often occur. Accordingly, unsupervised deep learning-based approaches, which learn the target image distribution,…

图像与视频处理 · 电气工程与系统科学 2022-07-15 Chanyong Jung , Joonhyung Lee , Sunkyoung You , Jong Chul Ye

Due to the potential risk of inducing cancers, radiation dose of X-ray CT should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts usually occur due to photon starvation, beamhardening, etc, which…

计算机视觉与模式识别 · 计算机科学 2018-02-07 Eunhee Kang , Junhong Min , Jong Chul Ye

Given the potential X-ray radiation risk to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. The current main stream low-dose CT methods include vendor-specific sinogram domain filtration and…

医学物理 · 物理学 2017-12-12 Hu Chen , Yi Zhang , Mannudeep K. Kalra , Feng Lin , Yang Chen , Peixi Liao , Jiliu Zhou , Ge Wang

Increasing use of CT in modern medical practice has raised concerns over associated radiation dose. Reduction of radiation dose associated with CT can increase noise and artifacts, which can adversely affect diagnostic confidence. Denoising…

计算机视觉与模式识别 · 计算机科学 2017-02-24 Qingsong Yang , Pingkun Yan , Mannudeep K. Kalra , Ge Wang

Denoising low-dose computed tomography (CT) images is a critical task in medical image computing. Supervised deep learning-based approaches have made significant advancements in this area in recent years. However, these methods typically…

图像与视频处理 · 电气工程与系统科学 2023-07-17 Xuan Liu , Yaoqin Xie , Jun Cheng , Songhui Diao , Shan Tan , Xiaokun Liang

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

图像与视频处理 · 电气工程与系统科学 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be…

计算机视觉与模式识别 · 计算机科学 2021-04-05 Wooram Kang , Mayank Patwari

In the intention of minimizing excessive X-ray radiation administration to patients, low-dose computed tomography (LDCT) has become a distinct trend in radiology. However, while lowering the radiation dose reduces the risk to the patient,…

医学物理 · 物理学 2022-04-12 Long Zhou , Xiaozhuang Wang , Min Hou , Ping Li , Chunlong Fu , Yanjun Ren , Tingting Shao , Xi Hu , Jihong Sun , Hongwei Ye

Positron emission tomography (PET) is widely used in various clinical applications, including cancer diagnosis, heart disease and neuro disorders. The use of radioactive tracer in PET imaging raises concerns due to the risk of radiation…

计算机视觉与模式识别 · 计算机科学 2017-12-13 Junshen Xu , Enhao Gong , John Pauly , Greg Zaharchuk
‹ 上一页 1 2 3 10 下一页 ›