中文
相关论文

相关论文: Geometric calibration of the SND detector electrom…

200 篇论文

The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer…

The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a…

The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 \div 1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of…

The program of upgrade of the Spherical Neutral Detector for future experiments at a new VEPP-2000 $e^+e^-$ collider is presented. Modernization includes upgrades of electromagnetic calorimeter, tracking system, detector electronics, data…

SND (Spherical Neutral Detector) is a general purpose nonmagnetic detector, successfully operating at Novosibirsk VEPP-2M collider during last four years in the center of mass energy range from 400 MeV up to 1400 MeV. Its crucial part is a…

The Very Large Area Gamma-ray Space Telescope Pathfinder (VLAST-P), as the technology validation satellite for the VLAST mission, is designed to observe high-energy solar bursts on orbit. The CsI electromagnetic calorimeter (ECAL) is one of…

Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.

仪器与探测器 · 物理学 2009-10-31 M. N. Achasov , D. A. Bukin , T. V. Dimova , V. P. Druzhinin , V. B. Golubev , V. N. Ivanchenko , A. A. Korol

The Multi-Purpose Detector (MPD) is designed to study a hot and dense baryonic matter formed in heavy-ion collisions at SQRT(sNN)=4-11 GeV at the NICA accelerator complex (Dubna, Russia). Large-sized electromagnetic calorimeter (ECal) of…

We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…

仪器与探测器 · 物理学 2019-08-15 Jaroslav Zalesak

Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic…

仪器与探测器 · 物理学 2016-02-17 Benedikt Vormwald , Jenny List , Annika Vauth

The technique of discrimination of the $e^+e^-\to e^+e^-$ and $e^+e^-\to \pi^+\pi^-$ events in energy range $0.5 < \sqrt{s} < 1$ GeV by energy deposition in the calorimeter of SND detector was developed by applying machine learning method.…

仪器与探测器 · 物理学 2017-02-01 M. N. Achasov , K. I. Beloborodov , A. S. Kupich

Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…

数据分析、统计与概率 · 物理学 2009-09-29 V. Karimaki , A. Heikkinen , T. Lampen , T. Linden

The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…

A silicon-based fine granularity calorimeter is a potential technology for the future International Linear Collider ILC, the future circular collider CEPC, and is also the chosen technology for the upgraded CMS experiment of the Large…

仪器与探测器 · 物理学 2017-08-02 Stathes Paganis , Andreas Psallidas , Arnaud Steen

A procedure has been developed for the charge, mass and energy calibration of ions produced in nuclear heavy ion reactions. The charge and mass identification are based on a $\Delta$E-E technique. A computer code determines the conversion…

核实验 · 物理学 2009-10-28 P. F. Mastinu , P. M. Milazzo , M. Bruno , M. D'agostino

For the radiative Bhabha calibration of BaBar's electromagnetic calorimeter, the measured energy of a photon cluster is being compared with the energy obtained via a kinematic fit involving other quantities from that event. The details of…

高能物理 - 实验 · 物理学 2007-05-23 Johannes M. Bauer

The geometric calibration of the Planck satellite is investigated, specifically those parameters which require the use of the science data for their extraction. Methods for the recovery of these geometric-calibration parameters from point…

天体物理学 · 物理学 2009-11-11 D. L. Harrison , F. van Leeuwen

The CALICE collaboration is developing a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon…

仪器与探测器 · 物理学 2012-02-01 Katsushige Kotera