中文
相关论文

相关论文: Calibration and GEANT4 Simulations of the Phase II…

200 篇论文

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

The quest for improved neutron capture cross sections for advanced reactor concepts, transmutation of radioactive wastes as well as for astrophysical scenarios of neutron capture nucleosynthesis has motivated new experimental efforts based…

We compare existing segmented plastic antineutrino detectors with our new geometrically improved design for antineutrino detection and light collection efficiency. The purpose of this study is to determine the most suitable design style for…

仪器与探测器 · 物理学 2019-03-07 Mustafa Kandemir , Altan Cakir

Fast neutron detection is often based on the neutron-proton elastic scattering reaction: the ionization caused by recoil protons in a hydrogenous material constitutes the basic information for the design and development of a class of…

Background and purpose: In-beam Positron Emission Tomography (PET) is one of the modalities that can be used for in-vivo non-invasive treatment monitoring in proton therapy. PET distributions obtained during various treatment sessions can…

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…

仪器与探测器 · 物理学 2009-10-06 R. McNabb , J. Blackburn , J. D. Crnkovic , D. W. Hertzog , B. Kiburg , J. Kunkle , E. Thorsland , D. M. Webber , K. R. Lynch

Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue,…

A plastic scintillator paddle detector with embedded fiber light guides and photomultiplier tube readout, referred to as the Reaction Plane Detector (RXNP), was designed and installed in the PHENIX experiment prior to the 2007 run of the…

Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…

仪器与探测器 · 物理学 2026-03-30 B. Li , Y. Ma , K. Ni

Pneumothorax, also called a collapsed lung, refers to the presence of the air in the pleural space between the lung and chest wall. It can be small (no need for treatment), or large and causes death if it is not identified and treated on…

图像与视频处理 · 电气工程与系统科学 2020-09-09 Ayat Abedalla , Malak Abdullah , Mahmoud Al-Ayyoub , Elhadj Benkhelifa

A NaI(Tl) detector array called DALI2 (Detector Array for Low Intensity radiation 2) has been constructed for in-beam $\gamma$-ray spectroscopy experiments with fast radioactive isotope (RI) beams. It consists typically of 186 NaI(Tl)…

核实验 · 物理学 2014-07-30 S. Takeuchi , T. Motobayashi , Y. Togano , M. Matsushita , N. Aoi , K. Demichi , H. Hasegawa , H. Murakami

The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of…

Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment…

The following thesis presents research which constitutes the first steps towards the construction of a novel SiFi-CC detector intended for real-time monitoring of proton therapy. The detector construction will be based on inorganic…

仪器与探测器 · 物理学 2023-06-21 Katarzyna Rusiecka

The present work is devoted to develop a computational model using the Gate Monte Carlo software for the simulation of a 6MV photon beam given by Elekta Synergy Platform medical linear accelerator treatment head. The model includes the…

医学物理 · 物理学 2013-09-04 Yahya Tayalati , Samir Didi , Mustafa Zerfaoui , Abdellilah Moussaa

An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer…

医学物理 · 物理学 2015-01-07 O. Actis , D. Meer , S. König

A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier…

医学物理 · 物理学 2008-05-27 Nobuyuki Kanematsu , Shunsuke Yonai , Azusa Ishizaki , Masami Torikoshi

The determination of relative stopping power (RSP) via proton computed tomography (pCT) of a patient is dependent in part on the knowledge of the incoming proton kinetic energies; the uncertainty in these energies is in turn determined by…

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed…