相关论文: Upgrade of Beam Energy Measurement System at BEPC-…
The Status of BEPCII/BESIII upgrade is described, BEPCII is designed to reach a luminosity of $10^{33}/cm^{-2}s^{-1}$ at c. m. energy of 3.89GeV, and BESIII detector is fully rebuilt. The project is on track and is progressing well. The…
Progress in electron-beam spectroscopies has recently enabled the study of optical excitations with combined space, energy and time resolution in the nanometer, millielectronvolt and femtosecond domain, thus providing unique access into…
The backscattering of laser radiation by a relativistic electron beam is a widely used method for measuring the spin polarization of electrons. We consider again the properties of the scattering process paying special attention to recoil…
A high-level beam background is a crucial challenge to future upgrades to the BEPCII collider. We report on the first separate measurement of the main beam background components at BEPCII. The separation measurement enables the beam…
The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was…
A novel interferometric method is presented for the measurement of the absolute energy of electron beams. In the year 2016, a pioneering experiment was performed using a 195 MeV beam of the Mainz Microtron (MAMI). The experimental setup…
The MEG II experiment searches for a charged-lepton-flavour-violating $\mu \to e \gamma$ with the target sensitivity of $6 \times 10^{-14}$. A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and…
We present a practical method to measure the energy of proton beams at a medical cyclotron using the stacked foil technique in combination with a Bayesian inference method. By measuring the $^{48}$V activity induced in a stack of irradiated…
We first introduce the design parameters of the Beijing Electron-Positron Collider II (BEPCII) and the simulation study of beam-beam effects during the design process of the machine. The main advances since 2007 are briefly introduced and…
The proof test and debugging of the multi-pulsed electron accelerator, Dragon-2,requires a thorough comprehension of the quality of the beams. This puts forward a rigid requirement on the measurement system that it should have the ability…
The STAR experiment at Brookhaven National Laboratory has completed data taking for the second phase of the beam energy scan (BES-II) program, including in a fixed-target (FXT) mode. The BES-II program has collected high-statistics data on…
In the framework of the LHC Injectors Upgrade project, the CERN Proton Synchrotron underwent hardware changes during the Long Shutdown 2. These changes required an update of the CERN Proton Synchrotron impedance model and an assessment of…
We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII detector. The control samples of the initial-state-radiation (ISR) process of $e^+e^-\rightarrow \gamma \mu^+\mu^-$ at…
On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. One candidate is a quadrupole pick-up. Therefore, a new type…
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($\gamma$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $\gamma\gamma$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900…
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the…
Research in non-perturbative QED in strong-field backgrounds has gained interest in recent years, due to advances in high-intensity laser technologies that make extreme fields accessible in the laboratory. One key signature of strong-field…
Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the…
This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It…
The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed…