相关论文: Beam Position Reconstruction for the g2p Experimen…
The g2p/GEp experiments used a solid NH3 polarized target, where the polarization of the target is sensitive to temperature and radiation. The beam current was limited to 5-100 nA during the experiment to avoid too much depolarization of…
An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer…
The main focus of beam alignment is to find the optimal beam which yields the largest received signal strength (RSS) with faster speed.In this paper, we demonstrate an efficient beam alignment scheme with our testbed. The algorithm we…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
A real-time beam profile monitoring system is proposed for GeV photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARiS; previously known as ELPH) at Tohoku University. This…
The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was…
The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time passive measurements without impacting the beam quality.…
Beam position monitor (BPM) can easily reinforce the handling of beam orbits and measure the absolute beam position [1]. Its data can be used to optimize and correct beam in both first turn and closed orbit mode. In order to set the…
The Qweak experiment aims to measure the weak charge of the proton to 4% via the parity-violating asymmetry ($\sim$-200 ppb) in elastic e+p scattering. The scattering rate is largely influenced by five beam parameters: horizontal position…
In the storage ring of PLS-II, we reduced mechanical displacement of electron beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The orbit feedback system intends that the electron beam pass through the center…
A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
We present a novel solution to automated beam alignment optimization. This device is based on a Raspberry Pi computer, stepper motors, commercial optomechanics and electronic devices, and the open source machine learning algorithm M-LOOP.…
Efficient beam alignment is a crucial component in millimeter wave systems with analog beamforming, especially in fast-changing vehicular settings. This paper proposes a position-aided approach where the vehicle's position (e.g., available…
A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…
Precise and accurate measurements of the beam energy delivered to the experimental halls at the Thomas Jefferson Accelerator Facility (Jefferson Lab) is required by many experiments for proper data analysis and physics event reconstruction.…
With a Bayesian Gaussian regression approach, a systematic method for analyzing a storage ring's beam position monitor (BPM) system requirements has been developed. The ultimate performance of a ring-based accelerator, based on brightness…
Accurate measuring the location and orientation of individual particles in a beam monitoring system is of particular interest to researchers in multiple disciplines. Among feasible methods, gaseous drift chambers with hybrid pixel sensors…