相关论文: Opticle fibre calibration system and adaptive powe…
In this paper, we describe the first tests of a dual-readout fiber calorimeter in which silicon photomultipliers are used to sense the (scintillation and Cherenkov) light signals. The main challenge in this detector is implementing a design…
In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC)…
Silicon Photomultipliers are potentially ideal detectors for Quantum Optics and Quantum Information studies based on mesoscopic states of light. However, their non-idealities hampered their use so far. An optimal mode of operation has been…
A method to precisely calibrate the oscillation amplitude in Dynamic Scanning Force Microscopy is described. It is experimentally shown that a typical electronics used to process the dynamic motion of the cantilever can be adjusted to…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
Optically levitated nanoparticles offer enormous potential for precision sensing. However, as for any other metrology device, the absolute measurement performance of a levitated-particle sensor is limited by the accuracy of the calibration…
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled…
The dimensions of liquid scintillator neutrino detectors have grown over the years. Thus, the analog cable length required for the readout increases. In consequence, the signal loss increases as well. With the intelligent Photomultiplier…
Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a…
We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241 alpha…
We present a description of the operation of a multi-pixel detector in the presence of non-negligible dark-count and cross-talk effects. We apply the model to devise self-consistent calibration strategies to be performed on the very light…
In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts,…
As the precision frontier of astrophysics advances towards the one millimagnitude level, flux calibration of photometric instrumentation remains an ongoing challenge. We present the results of a lab-bench assessment of the viability of…
Photon detectors like the ALICE Calorimeters are vulnerable to both optical and electrical crosstalk between detector channels belonging to the same particle event. In order to quantify the crosstalk generated by a single channel on its…
A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam program, in order to study the possibilities of extending…
An innovative path for the detectors at future colliders to achieve higher performances is to use a Particle Flow approach, which requires highly granular calorimeters to image individual showers. The silicon-tungsten electromagnetic…
This report presents the design, characterization, and application of a high-sensitivity optical detection system based on plastic scintillators coupled to Multi-Pixel Photon Counters (MPPCs). The primary objective was to evaluate the…
A beam monitor detector prototype based on doped silica fibres coupled to optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. Scintillation light produced by Ce and Sb doped silica…
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…