中文
相关论文

相关论文: Fast Scatter Artifacts Correction for Cone-Beam CT…

200 篇论文

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray…

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed and validated a method which uses these projections to…

医学物理 · 物理学 2015-01-15 Bernard L. Jones , David Westerly , Moyed Miften

Deep convolutional neural networks (DCNN) have demonstrated its capability to convert MR image to pseudo CT for PET attenuation correction in PET/MRI. Conventionally, attenuated events are corrected in sinogram space using attenuation maps…

计算机视觉与模式识别 · 计算机科学 2019-05-22 Jaewon Yang , Dookun Park , Jae Ho Sohn , Zhen Jane Wang , Grant T. Gullberg , Youngho Seo

AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission…

医学物理 · 物理学 2022-06-22 Ida Häggström , Lukas M. Carter , Thomas J. Fuchs , Adam L. Kesner

Recent developments in artificial intelligence technology have enabled new developments that can improve attenuation and scatter correction in PET and SPECT. These technologies will enable the use of accurate and quantitative imaging…

医学物理 · 物理学 2021-08-30 Alan B. McMillan , Tyler J. Bradshaw

Conebeam CT using a circular trajectory is quite often used for various applications due to its relative simple geometry. For conebeam geometry, Feldkamp, Davis and Kress algorithm is regarded as the standard reconstruction method, but this…

图像与视频处理 · 电气工程与系统科学 2020-06-04 Yoseob Han , Junyoung Kim , Jong Chul Ye

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations…

Traditional dictionary learning based CT reconstruction methods are patch-based and the features learned with these methods often contain shifted versions of the same features. To deal with these problems, the convolutional sparse coding…

医学物理 · 物理学 2018-10-16 Peng Bao , Wenjun Xia , Kang Yang , Jiliu Zhou , Yi Zhang

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

图像与视频处理 · 电气工程与系统科学 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Ring artifacts are common artifacts in CT imaging, typically caused by inconsistent responses of detector units to X-rays, resulting in stripe artifacts in the projection data. Under circular scanning mode, such artifacts manifest as…

图像与视频处理 · 电气工程与系统科学 2025-04-16 Yunze Liu , Congyi Su , Xing Zhao

The single-scatter approximation is fundamental in many tomographic imaging problems including x-ray scatter imaging and optical scatter imaging for certain media. In all cases, noisy measurements are affected by both local scatter events…

图像与视频处理 · 电气工程与系统科学 2021-04-21 Michael R. Walker , Joseph A. O'Sullivan

For long time non-pure beta emitters are avoided from PET imaging due to extra dose and increase in background from Compton scattering. But advent of high-resolution Compton camera system opens up new domain of imaging. Various non-pure…

医学物理 · 物理学 2021-10-06 Satyajit Ghosh , Pragya Das

The purpose of this study is to develop a deep learning based method that can automatically generate segmentations on cone-beam CT (CBCT) for head and neck online adaptive radiation therapy (ART), where expert-drawn contours in planning CT…

医学物理 · 物理学 2021-02-02 Xiao Liang , Howard Morgan , Dan Nguyen , Steve Jiang

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…

医学物理 · 物理学 2016-10-18 Steven Tilley , Wojciech Zbijewski , Jeffrey H. Siewerdsen , J. Webster Stayman

To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the…

图像与视频处理 · 电气工程与系统科学 2024-12-30 Haotian Zhao , Ruifeng Chen , Jing Yan , Juan Feng , Jun Xiang , Yang Chen , Dong Liang , Yinsheng Li

Image denoising techniques are essential to reducing noise levels and enhancing diagnosis reliability in low-dose computed tomography (CT). Machine learning based denoising methods have shown great potential in removing the complex and…

计算机视觉与模式识别 · 计算机科学 2017-08-29 Dufan Wu , Kyungsang Kim , Georges El Fakhri , Quanzheng Li

Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid…

图像与视频处理 · 电气工程与系统科学 2019-12-02 Alexander Preuhs , Michael Manhart , Philipp Roser , Bernhard Stimpel , Christopher Syben , Marios Psychogios , Markus Kowarschik , Andreas Maier

Inspired by the success of deep learning applications on restoration of low-dose and sparse CT images, we propose a novel method to reconstruct high-quality 4D cone-beam CT (4DCBCT) images from sparse datasets. Our approach combines the…

医学物理 · 物理学 2018-08-14 Joel Beaudry , Pedro L. Esquinas

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

图像与视频处理 · 电气工程与系统科学 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw…

图像与视频处理 · 电气工程与系统科学 2024-10-01 Ziheng Deng , Hua Chen , Yongzheng Zhou , Haibo Hu , Zhiyong Xu , Jiayuan Sun , Tianling Lyu , Yan Xi , Yang Chen , Jun Zhao