相关论文: Single-scan scatter correction in CBCT by using pr…

200 篇论文

In this paper, an improved scatter correction with moving beam stop array (BSA) for x-ray cone beam (CB) CT is proposed. Firstly, correlation between neighboring CB views is deduced based on John's Equation. Then, correlation-based…

医学物理 · 物理学 2014-10-31 Hao Yan , Xuanqin Mou , Shaojie Tang , Qiong Xu

Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter…

医学物理 · 物理学 2016-08-03 Kuidong Huang , Zhe Xu , Dinghua Zhang , Hua Zhang , Wenlong Shi

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

医学物理 · 物理学 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

医学物理 · 物理学 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

医学物理 · 物理学 2016-04-07 Shi-peng Xie , Rui-ju Yan

With the emergence of CNT (Carbon nanotube), static and instant CT scanning becomes possible. By transforming the traditionally rotated thermal source into a static ring array source composed of multiple CNTs, the imaging system can achieve…

医学物理 · 物理学 2025-02-11 Jiayu Duan , Yang Li , Jianmei Cai , Xuanqin Mou

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

医学物理 · 物理学 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

计算机视觉与模式识别 · 计算机科学 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

医学物理 · 物理学 2022-05-24 Junbo Peng

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

医学物理 · 物理学 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

图像与视频处理 · 电气工程与系统科学 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT)…

CBCT images suffer from acute shading artifacts primarily due to scatter. Numerous image-domain correction algorithms have been proposed in the literature that use patient-specific planning CT images to estimate shading contributions in…

计算机视觉与模式识别 · 计算机科学 2018-01-18 Awais Ashfaq , Jonas Adler

In this work, we compare one-step and two-step approaches for X-ray computed tomography (CT) scatter correction and density reconstruction. X-ray CT is an important imaging technique in medical and industrial applications. In many cases,…

图像与视频处理 · 电气工程与系统科学 2023-01-11 Alexander N. Sietsema , Michael T. McCann , Marc L. Klasky , Saiprasad Ravishankar

Cone-beam computed tomography (CBCT) is a critical 3D imaging technology in the medical field, while the high radiation exposure required for high-quality imaging raises significant concerns, particularly for vulnerable populations.…

图像与视频处理 · 电气工程与系统科学 2026-03-10 Yiqun Lin , Jixiang Chen , Hualiang Wang , Jiewen Yang , Jiarong Guo , Yi Zhang , Xiaomeng Li

Layover separation has been fundamental to many synthetic aperture radar applications, such as building reconstruction and biomass estimation. Retrieving the scattering profile along the mixed dimension (elevation) is typically solved by…

信号处理 · 电气工程与系统科学 2021-07-07 Yuanyuan Wang , Xiao Xiang Zhu

Cone beam computed tomography (CBCT) is an important imaging technology widely used in medical scenarios, such as diagnosis and preoperative planning. Using fewer projection views to reconstruct CT, also known as sparse-view reconstruction,…

图像与视频处理 · 电气工程与系统科学 2024-06-07 Yiqun Lin , Jiewen Yang , Hualiang Wang , Xinpeng Ding , Wei Zhao , Xiaomeng Li

Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction…

医学物理 · 物理学 2024-12-18 Xin Zhang , Ting Su , Jiongtao Zhu , Hairong Zheng , Dong Liang , Yongshuai Ge

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…

医学物理 · 物理学 2016-10-18 Steven Tilley , Wojciech Zbijewski , Jeffrey H. Siewerdsen , J. Webster Stayman

In this paper, we present a method for single-shot blind deconvolution incorporating a coded aperture (CA). In this method, we utilize the CA, inserted on the pupil plane, as support constraints in blind deconvolution. Not only an object…

图像与视频处理 · 电气工程与系统科学 2022-08-03 Hideyuki Muneta , Ryoichi Horisaki , Yohei Nishizaki , Makoto Naruse , Jun Tanida