Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase…
X-ray Talbot-Lau interferometer has been used widely to conduct phase contrast imaging with a conventional low-brilliance x-ray source. Typically, in this technique, background correction has to be performed in order to obtain the pure…
X-ray interferometry provides valuable information in terms of attenuation, small-angle scatter, and differential phase contrast. This multi-modal contrast can aid in many clinical applications, such as lung diseases and breast cancer.…
Recently, the dual-phase grating based X-ray differential phase contrast imaging technique has shown better radiation dose efficiency performance than the Talbot-Lau system. In this paper, we provide a theoretical analyses framework derived…
Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is Talbot interferometry, which, combined with energy-sensitive…
Two-dimensional Talbot array illuminators (TAIs) were designed, fabricated, and evaluated for high-resolution high-contrast x-ray phase imaging of soft tissue at 10-20keV. The TAIs create intensity modulations with a high compression ratio…
As a multi-contrast X-ray computed tomography (CT) imaging system, the grating-based Talbot-Lau interferometer is able to generate the absorption contrast and differential phase contrast (DPC) images concurrently. However, experiments found…
We study in detail a peculiar configuration of the Talbot-Lau matter wave interferometer, characterised by unequal distances between the two diffraction gratings and the observation plane. We refer to this apparatus as the "asymmetric…
Medical differential phase contrast x-ray imaging (DPCI) promises improved soft-tissue contrast at lower x-ray dose. The dose strongly depends on both the angular sensitivity and on the visibility of a grating-based Talbot-Lau…
To implement dual phase grating x-ray interferometry with x-ray tubes, one needs to incorporate an absorbing source grating. In order to attain good fringe visibility, the period of a source grating should be subject to a stringent…
Purpose: Grating-based X-ray phase-contrast imaging is a promising modality increasing the soft tissue contrast in medical imaging. In this work, the signature of lung tissue in X-ray grating-based physe-contrast imaging is investigated.…
A device based on a three-block Fresnel zone plate interferometer is proposed for hard X-ray phase-contrast imaging. The device combines a low requirement for the coherence of the initial radiation (the interferometer operates in the…
The invention of X-ray interferometers has led to advanced phase-sensing devices that are invaluable in various applications. These include the precise measurement of universal constants, e.g. the Avogadro number, of lattice parameters of…
A concept to measure the neutron electric charge is presented which employs a precision Talbot-Lau interferometer in a high-intensity pulsed neutron beam. It is demonstrated that the sensitivity for a neutron charge measurement can be…
Modern x-ray light sources promise access to structure and dynamics of matter in largely unexplored spectral regions. However, the desired information is encoded in the light intensity and phase, whereas detectors register only the…
Recently, X-ray interferometers with more than one phase grating have been developed for differential phase contrast (DPC) imaging. In this study, a novel framework is developed to predict such interferometers' angular sensitivity responses…
Talbot-Lau X-ray phase-contrast imaging is a novel imaging modality, which provides not only an X-ray absorption image, but also additionally a differential phase image and a dark-field image. The dark-field image is related to small angle…
Transient absorption microscopy measures excited-state kinetics based on the imaginary part of the pump-induced perturbation to the complex refractive index, i.e. $\Im \{\Delta\mathcal N\}$, with applications in both materials and…
Starting from an elementary model and refining it to take into account more realistic effects, we discuss the limitations and advantages of matter-wave interferometry in different configurations. We focus on the possibility to apply this…
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research.…