相关论文: Stabilizing a Fabry-Perot etalon to 3 cm/s for spe…
Precise wavelength calibration is a critical issue for high-resolution spectroscopic observations. The ideal calibration source should be able to provide a very stable and dense grid of evenly distributed spectral lines of constant…
We report on the construction and testing of a vacuum-gap Fabry-P\'erot etalon calibrator for high precision radial velocity spectrographs. Our etalon is traced against a rubidium frequency standard to provide a cost effective, yet…
An optical etalon illuminated by a white light source provides a broadband comb-like spectrum that can be employed as a calibration source for astronomical spectrographs in radial velocity (RV) surveys for extrasolar planets. For this…
Accurate wavelength calibration is an important factor for any measurement with high resolution spectrographs. Stellar spectrum comprises of discrete absorption or emission lines whose position is precisely determined by calibrating the…
The study of Earth-mass extrasolar planets via the radial-velocity technique and the measurement of the potential cosmological variability of fundamental constants call for very-high-precision spectroscopy at the level of…
Wavelength calibration is a key factor for high-resolution spectroscopic measurements for precision radial velocities. Hollow-cathode lamps (e.g., ThAr), absorption cells (e.g., iodine cell), dielectric coated Fabry-P\'erot etalons and…
We present a stabilization technique developed to lock and dynamically tune the resonant frequency of a moderate finesse Fabry-P\'erot (FP) cavity used in precision atom-cavity quantum electrodynamics (QED) experiments. Most experimental…
We have performed high resolution spectroscopy of rubidium with a single mode continuous wave distributed feedback (DFB) laser diode. The saturation spectrum of the D_2-line of 85Rb and 87Rb was recorded with a resolution close to the…
The comb-like spectrum of a white light-illuminated Fabry-P\'{e}rot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (100's of nm)…
Over the past decades hollow-cathode lamps have been calibration standards for spectroscopic measurements. Advancing to cm/s radial velocity precisions with the next generation of instruments requires more suitable calibration sources with…
A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT), Kavalur, has been in operation since 2005. Owing to various technological advancements in precision spectroscopy in recent years, several research avenues have been…
We describe the design, construction, and characterization of a medium-finesse Fabry-P\'erot cavity for simultaneous frequency stabilization of two lasers operating at 960 and 780 nm wavelengths, respectively. The lasers are applied in…
We present and characterize a laser system for the spectroscopy on highly-charged ^209Bi^82+ ions at a wavelength of 243.87 nm. For absolute frequency stabilization, the laser system is locked to a near-infra-red laser stabilized to a…
We demonstrate a technique for frequency measurements of atomic transitions with a precision of 30 kHz. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the $D_2$ line of…
Rubidium two-photon frequency standards are emerging as powerful contenders for compact, durable devices with exceptional stability. The field has focused on single-color excitation to date. Here we demonstrate the key advantages of a…
An experimental method is developed for the robust frequency stabilization using a high-finesse cavity when the laser exhibits large intermittent frequency jumps. This is accomplished by applying an additional slow feedback signal from…
The Echelle spectrograph operating at Vainu Bappu Telescope (VBT) is a general purpose instrument designed for high resolution spectroscopy. It is being considered for precision Doppler measurements without altering the existing design and…
The CHIRON optical high-resolution echelle spectrometer was commissioned at the 1.5m telescope at CTIO in 2011. The instrument was designed for high throughput and stability, with the goal of monitoring radial velocities of bright stars…
We present a general analysis for determining the optimal modulation parameters for the modulation transfer spectroscopy scheme. The results are universally valid and can be applied to spectroscopy of any atomic species requiring only the…
We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan…