中文
相关论文

相关论文: Contributing to TAI with a Secondary Representatio…

200 篇论文

SI-traceable measurements of optical frequencies using International Atomic Time (TAI) do not require a local primary frequency reference, but suffer from an uncertainty in tracing to the SI second. For the measurement of the $^{87}$Sr…

原子物理 · 物理学 2017-04-05 Hidekazu Hachisu , Gérard Petit , Fumimaru Nakagawa , Yuko Hanado , Tetsuya Ido

The absolute frequency of the $^{87}{\rm Sr}$ clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was…

原子物理 · 物理学 2017-02-01 Hidekazu Hachisu , Gérard Petit , Tetsuya Ido

The current SI second based on the atomic hyperfine transition in the ground state of 133Cs is expected to be replaced by a new definition based on optical frequency standards, whose estimated uncertainty has now been established two orders…

原子物理 · 物理学 2019-11-14 Jérôme Lodewyck

Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical…

The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave…

The current methods for realization of the second with the highest accuracy through the frequency of the hyperfine transition between two levels of the ground state of the cesium 133 atom are considered. It is discussed possible ways for…

原子物理 · 物理学 2021-02-12 Viacheslav V. Khruschov

The atomic transitions employed in the best of today's optical clocks are a strong foundation for the upcoming redefinition of the SI second. Including multiple transitions in the definition offers increased accuracy, a robust diversity of…

原子物理 · 物理学 2025-05-27 Claudio Eligio Calosso , Nils Nemitz

This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures (CIPM). This update focused on a subset…

原子物理 · 物理学 2024-01-29 H S Margolis , G Panfilo , G Petit , C Oates , T Ido , S Bize

The current definition of the SI second is based on the 133Cs ground-state hyperfine transition in the microwave domain, with the most accurate realizations achieving fractional frequency uncertainties of about (1-2)E16. In contrast,…

原子物理 · 物理学 2026-03-17 Fang Fang , Chaowei Wang , Yani Zuo , Shaoyang Dai

The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical…

The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the…

Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further…

原子物理 · 物理学 2018-10-22 S. Weyers , V. Gerginov , M. Kazda , J. Rahm , B. Lipphardt , G. Dobrev , K. Gibble

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic…

We give an overview of the work done with the Laboratoire National de M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble,…

Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent…

We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit…

In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the…

We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14…

Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition…

‹ 上一页 1 2 3 10 下一页 ›