相关论文: Experimental study of electric breakdowns in liqui…
This paper describes the results of a study on the general lines, main construction criteria, crucial points, parameters and required preliminary R&D activities for the construction of a LAr (liquid argon) imaging detector with active mass…
The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…
Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…
Breakdown voltages of a capacitively coupled radio frequency argon discharge at 27 MHz are studied. We use a one-dimensional electrostatic PIC code to investigate the effect of changing the secondary emission properties of the electrodes on…
The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength…
Large liquid argon (LAr) detectors, up to 100 kton scale, are presently being considered for proton decay searches and neutrino astrophysics as well as far detectors for the next generation of long baseline neutrino oscillation experiments,…
We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…
We report on the successful operation of a double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) equipped with two dimensional projective anodes with dimensions 10$\times$10 cm$^2$, and with a maximum…
The cross section for neutron interactions on argon is an important design and operational parameter for a number of neutrino, dark matter, and neutrinoless double beta decay experiments which use liquid argon as a detection or shielding…
We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an…
Liquid argon technology is widely used by many previous and current neutrino experiments, and it is also promising for future large-scale neutrino experiments. When detecting neutrinos using liquid argon, many hadrons are involved, which…
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high…
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross…
A measurement of ionization yields in noble-gas liquids is relevant to the energy calibration of nuclear recoil detectors for dark matter search and coherent neutrino-nucleus scattering experiments. In this work we further study the…
A device has been built and tested, in which a ceramic superconducting cathode and a copper anode cause electrical discharges in low pressure gases, at temperatures between 50 and 70 K. The electrodes are connected to a capacitors array…
This article presents an investigation of a transient (30 {\mu}s - 5 ms) electrical discharge in metal vapour with low voltage (< 50 V) and current (< 1 A), drawn between two separating electrodes. Discharges of this type are rarely…
The sensitivity of our liquid argon purity measurement -around 0.03%- leads us to refine the tools used classically in this field. First we introduce an analytical form describing the spectrum of a 207Bi source for different values of…
A scalable line of liquid argon TPC detectors is described, based on a three dimensional cubic frame array immersed on a common liquid argon volume. The paper describes general lines, main construction criteria, crucial points, parameters…
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification,…
A parametric study of an underwater pulsed plasma discharge in pin-to-pin electrode configuration has been performed. The influence of two parameters has been reported, the water conductivity (from 50 to 500 $\mu$S/cm) and the applied…