相关论文: A strontium lattice clock with $3 \times 10^{-17}$…
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the…
Aided by ultra-high resolution spectroscopy, the overall systematic uncertainty of the $^{1}S_{0}$-$^{3}P_{0}$ clock resonance for lattice-confined $^{87}$Sr has been characterized to $9\times10^{-16}$. This uncertainty is at a level…
We report the absolute frequency measurement of the 5s2 1S0-5s5p 3P0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center (NTSC). Its systematic frequency shifts are evaluated carefully with a total relative…
With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help…
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…
We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain…
The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the…
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…
We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty…
Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of…
We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total…
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic…
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is…
The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the…
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische…
We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14…
We report a measurement of the absolute frequency of the 1S0-3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via TAI…
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a…
We demonstrate a precision frequency measurement using a phase-stabilized 120-km optical fiber link over a physical distance of 50 km. The transition frequency of the 87Sr optical lattice clock at the University of Tokyo is measured to be…
We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to…