相关论文: Absorbed Dose in Ion Beams: Comparison of Ionisati…
Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application.…
Previously reported nanodosimetric measurements of therapeutic-energy carbon ions penetrating simulated tissue have produced results that are incompatible with the predicted mean energy of the carbon ions in the nanodosimeter and previous…
A Cherenkov detector based on an array of five lead fluoride ($\beta$-PbF$_2$) crystals of size 30 mm$\times$30 mm$\times$160 mm read out by reverse-type avalanche photodiodes (APD's) of active area 10 mm$\times$10 mm was used to measure…
Detectors planned for use at the Large Hadron Collider will operate in a radiation field produced by beam collisions. To predict the radiation damage to the components of the detectors, prototype devices are irradiated at test beam…
The resistivity of polycrystalline chemical vapor deposition diamond sensors is studied in samples exposed to fluences relevant to the environment of the High Luminosity Large Hadron Collider. We measure the leakage current for a range of…
The optical properties of the ice at the geographical South Pole have been investigated at depths between 0.8 and 1 kilometers. The absorption and scattering lengths of visible light ($\sim$515 nm) have been measured {\it in situ } using…
A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at…
The transmission of silicon crystals irradiated by 24 GeV/c protons and reactor neutrons has been measured for photon energies, $E{\gamma}$, between 0.95 and 1.3 eV. From the transmission data the absorption coefficient ${\alpha}$ is…
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation.…
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY…
We report on simulations and measurements of the optical absorption of silicon nanowires (NWs) versus their diameter. We first address the simulation of the optical absorption based on two different theoretical methods : the first one,…
Proton scattering in some water and tissue equivalent phantom materials was measured to evaluate their simulation accuracy of water and respective human biological tissues. The measurements were performed on the medical facility of the ITEP…
This Letter reports a measurement of the flux and energy spectrum of electron antineutrinos from six 2.9~GW$_{th}$ nuclear reactors with six detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1,579~m)…
All physical interactions are mediated by forces. Ultra-sensitive force measurements are therefore a crucial tool for investigating the fundamental physics of magnetic, atomic, quantum, and surface phenomena. Laser cooled trapped atomic…
The collimation efficiency for Pb ion beams in the LHC is predicted to be lower than requirements. Nuclear fragmentation and electromagnetic dissociation in the primary collimators create fragments with a wide range of Z/A ratios, which are…
We have determined the depth-dose curve, the penetration range, and the water equivalent ratio (WER), for proton beams of clinical energies in cortical bone, by means of a detailed and accurate simulation that combines molecular dynamics…
First detections of thermal water vapor absorption lines have been made toward Orion IRc2 using the Short Wavelength Spectrometer (SWS) on board the Infrared Space Observatory (ISO). Grating spectra covering wavelengths 25-45 micron yield…
The reliable operation of micro and nanomechanical devices necessitates a thorough knowledge of the water film thickness present on the surfaces of these devices with an accuracy in the nm range. In this work, the thickness of an ultra-thin…
In order to facilitate IR absorption measurements of mass-selected ions isolated in cryogenic matrices, we have upgraded an ion beam deposition apparatus encompassing a Bruker IFS66v/S FTIR spectrometer. A synthetic diamond beam splitter…
This study conceptualizes electronic dose to water, which is the radiation energy imparted to a unit mass of water by electronic interactions. The new dosimetry framework excludes nuclear interactions and consequently associated corrections…