相关论文: Beam test of a one-dimensional position sensitive …
A triple-GEM detector with two-dimensional readout is developed. The detector provides high position resolution for powder diffraction experiments at synchrotron radiation. Spatial resolution of the detector is measured in the lab using a…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
A new procedure aiming at folding a powder diffraction 2-D into a 1-D scan is presented. The technique consists of three steps: tracking the beam centre by means of a Simulated Annealing (SA) of the diffraction rings along the same axis,…
Single particle diffraction imaging experiments at free-electron lasers (FEL) have a great potential for structure determination of reproducible biological specimens that can not be crystallized. One of the challenges in processing the data…
We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
In radiation beam-profile measurements, an accurate positioning of the detector with high position resolution is essential. For this purpose, we built a scanning device capable of moving a detector in three dimensions using mainly parts…
The Shanghai Synchrotron Radiation Facility (SSRF) contains a 3.5-GeV storage ring serving as a national X-ray synchrotron radiation user facility characterized by a low emittance and a low coupling. The stability and quality of the…
Diffraction analysis in four dimensional scanning transmission electron microscopy now enables the mapping of local structures including symmetry, strain, and polarization of materials. However, measuring the distribution of these…
Synchrotron powder diffraction data were measured on various gas hydrates prepared at different fugacities and recovered to low temperatures. The data extend to sin {\theta}/{\lambda} values of at least 1.01 {\AA}-1, in some cases up to…
Information on the lattice parameter of single crystals with known crystallographic structure allows for estimations of sample quality and composition. In many cases it is suffcient to determine one lattice parameter or the lattice spacing…
Understanding the interactions between microstructure, strain, phase, and material behavior is crucial in many scientific fields. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and…
Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute…
We have grown intermetallic ErPd$_2$Si$_2$ single crystals employing laser-diodes with the floating-zone method. The temperature-dependent crystallography was determined using synchrotron and in-house X-ray powder diffraction measurements…
The development of synchrotron radiation light sources has been going on for decades. Recently, X-ray free-electron lasers as well as the fourth-generation synchrotron radiation sources based on multiple bend achromat lattices are…
A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…
A one-coordinate gaseous detector of soft X-ray photons for wide-angle X-ray scattering (WAXS) studies is being developed. The detector operates in counting mode and is based on multi-stage Gas Electron Multiplier(GEM). Full size detector…
A common way of speeding up powder diffraction measurements is the use of one or two dimensional detectors. This usually goes along with worse resolution and asymmetric peak profiles. In this work the influence of a straight linear detector…
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of…
A flexible apparatus for calibration of the absolute flux at the focal plane of the X-ray Source of a Powder Diffractometer, based on a fast scintillator counter, is presented. The measured fluxes, depending on the high voltage on the X-ray…