中文
相关论文

相关论文: Dynamic Bowtie for Fan-beam CT

200 篇论文

Patients undergoing a mechanical thrombectomy procedure usually have a multi-detector CT (MDCT) scan before and after the intervention. The image quality of the flat panel detector CT (FDCT) present in the intervention room is generally…

图像与视频处理 · 电气工程与系统科学 2025-08-28 Hélène Corbaz , Anh Nguyen , Victor Schulze-Zachau , Paul Friedrich , Alicia Durrer , Florentin Bieder , Philippe C. Cattin , Marios N Psychogios

The recent application of Fourier Based Iterative Reconstruction Method (FIRM) has made it possible to achieve high-quality 2D images from a fan beam Computed Tomography (CT) scan with a limited number of projections in a fast manner. The…

图像与视频处理 · 电气工程与系统科学 2020-06-24 N. Teyfouri , H. Rabbani , R. Kafieh , Iraj Jabbari

We propose a new algorithm to compute the X-ray transform of an image represented by unit (pixel/voxel) basis functions. The fundamental issue is equivalently calculating the intersection lengths of the ray with associated units. For any…

数值分析 · 数学 2024-08-28 Chong Chen , Runqian Wang , Chandrajit Bajaj , Ozan Öktem

In current clinical practice, noisy and artifact-ridden weekly cone-beam computed tomography (CBCT) images are only used for patient setup during radiotherapy. Treatment planning is done once at the beginning of the treatment using…

图像与视频处理 · 电气工程与系统科学 2022-01-02 Navdeep Dahiya , Sadegh R Alam , Pengpeng Zhang , Si-Yuan Zhang , Anthony Yezzi , Saad Nadeem

Diagnostic X (D-X) transport system would extract the beam from the downstream transport line of the second- axis of the Dual Axis Radiographic Hydrodynamic Test facility (DARHT-II) and transport this beam to the D-X firing point via four…

加速器物理 · 物理学 2007-05-23 Yu-Jiuan Chen , Arthur C. Paul

The limited availability of bronchoscopy images makes image synthesis particularly interesting for training deep learning models. Robust image translation across different domains -- virtual bronchoscopy, phantom as well as in-vivo and…

图像与视频处理 · 电气工程与系统科学 2025-07-03 Ahmad Soliman , Ron Keuth , Marian Himstedt

Daily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld…

医学物理 · 物理学 2026-03-09 Junbo Peng , Huiqiao Xie , Tonghe Wang , Xiangyang Tang , Xiaofeng Yang

We demonstrate dark-field x-ray microtomography in a compact, laboratory-based system capable of resolving attenuation, phase, and anisotropic scattering signals with micrometer-scale resolution across centimetre-scale samples. The method…

Purpose: 4D CBCT is a beneficial tool for the treatment of movable tumors, because it can help us to understand where the tumors are actually located and have a precise treatment plan. However, there is a limitation that general CBCT images…

Visual dynamic complexity is a ubiquitous, hidden attribute of the visual world that every dynamic vision system is faced with. However, it is implicit and intractable which has never been quantitatively described due to the difficulty in…

机器人学 · 计算机科学 2021-05-21 Qinbing Fu , Tian Liu , Xuelong Sun , Huatian Wang , Jigen Peng , Shigang Yue , Cheng Hu

In optical metrology, grating-like structures are used as tools to evaluate the performance of lithographic techniques. In particular, several shape parameters characterize those structures. One of them, termed side-wall angle, suffers from…

光学 · 物理学 2015-10-21 Luca Cisotto , Paul H. Urbach

This report is dedicated to a short motivation and description of our contribution to the AAPM DL-Sparse-View CT Challenge (team name: "robust-and-stable"). The task is to recover breast model phantom images from limited view fanbeam…

机器学习 · 计算机科学 2021-06-02 Martin Genzel , Jan Macdonald , Maximilian März

Two-directional beam-tracking (2DBT) is a method for phase-contrast imaging and tomography that uses an intensity modulator to structure the X-ray beam into an array of independent circular beamlets that are resolved by a high-resolution…

Visual information, captured for example by cameras, can effectively reflect the sizes and locations of the environmental scattering objects, and thereby can be used to infer communications parameters like propagation directions, receiver…

信号处理 · 电气工程与系统科学 2022-07-26 Weihua Xu , Feifei Gao , Xiaoming Tao , Jianhua Zhang , Ahmed Alkhateeb

In many analyses in Higgs, top and electroweak physics, the kinematic reconstruction of the final state is improved by constrained fits. This is a particularly powerful tool at $e^{+}e^{-}$ colliders, where the initial state four-momentum…

高能物理 - 实验 · 物理学 2021-11-30 Yasser Radkhorrami , Jenny List

We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation,…

医学物理 · 物理学 2022-08-26 G. Lioliou , O. Roche i Morgó , S. Marathe , K. Wanelik , S. Cipiccia , A. Olivo , C. K. Hagen

A new technique for reliably identifying point sources in millimeter/sub-millimeter wavelength maps is presented. This method accounts for the frequency dependence of noise in the Fourier domain as well as non-uniformities in the coverage…

天体物理仪器与方法 · 物理学 2015-06-15 T. A. Perera , G. W. Wilson , K. S. Scott , J. E. Austermann , J. R. Schaar , A. Mancera

A Bayesian data assimilation scheme is formulated for advection-dominated or hyperbolic evolutionary problems, and observations. The method is referred to as the dynamic likelihood filter because it exploits the model physics to dynamically…

动力系统 · 数学 2017-04-26 Juan M. Restrepo

Introduction: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods: A 7-layer neural network…

医学物理 · 物理学 2024-05-22 Ouri Cohen , Soudabeh Kargar , Sungmin Woo , Alberto Vargas , Ricardo Otazo

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who…

医学物理 · 物理学 2015-05-18 Xun Jia , Yifei Lou , Ruijiang Li , William Y. Song , Steve B. Jiang