相关论文: Hadronic energy resolution of a highly granular sc…
The hadron energy resolution of a highly granular CALICE analogue scintillator-steel hadronic calorimeter was studied using pion test beam data. The stochastic term contribution to the energy resolution was estimated to be 58%/sqrt(E/GeV).…
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The…
This paper discusses the hadronic energy reconstruction of two combined electromagnetic and hadronic calorimeter systems using physics prototypes of the CALICE collaboration: the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) and…
The CALICE collaboration has constructed highly granular hadronic and electromagnetic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses 7608 small…
The particles produced at a potential Future Circular Collider with $\sqrt{s}$ = 100 TeV are of unprecented energies. In this document we present the hadronic shower containment and resolution parametrizations based on Geant4 simulations…
The software compensation algorithms developed for the CALICE Analog Hadron Calorimeter are extended to incorporate time information on the cell level, and the performance is studied in GEANT4 simulations with a detector model of a…
An improved weighting algorithm applied to hadron showers has been developed for a fine grained LAr calorimeter. The new method uses tabulated weights which depend on the density of energy deposited in individual cells and in a surrounding…
The fluctuations in energy loss to processes that do not generate measurable signals, such as binding energy losses, set the limit on achievable hadronic energy resolution in traditional energy reconstruction techniques. The correlation…
A new method for calibrating the hadron response of a segmented calorimeter is developed. It is based on a principal component analysis of the calorimeter layer energy deposits, exploiting longitudinal shower development information to…
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting…
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from…
The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been…
If the response to a hadronic shower in a semi-infinite uniform calorimeter structure is $S$ relative to the electronic response, then $S/E = [\fem + (1-\fem)(h/e)]$, where $E$ is the incident hadron energy, $\fem$ is the electronic shower…
The highly granular calorimeter prototypes of the CALICE collaboration have provided large data samples with precise three-dimensional information on hadronic showers with steel and tungsten absorbers and silicon, scintillator and gas…
We investigate the effect of longitudinal and transverse calorimeter segmentation on event-by-event software compensation for hadronic showers. To factorize out sampling and electronics effects, events are simulated in which a single…
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating…
The SDHCAL technological prototype that has been completed in 2012 was exposed to beams of pions and electrons of different energies at the CERN SPS for a total time period of 5 weeks. The data has been analyzed within the CALICE…
Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic…
The lateral and longitudinal profiles of hadronic showers detected by a prototype of the ATLAS Iron-Scintillator Tile Hadron Calorimeter have been investigated. This calorimeter uses a unique longitudinal configuration of scintillator…
The lateral and longitudinal profiles of hadronic showers detected by a prototype of the ATLAS Iron-Scintillator Tile Hadron Calorimeter have been investigated. This calorimeter uses a unique longitudinal configuration of scintillator…