We report on the first large-scale production of low radioactivity argon from underground gas wells. Low radioactivity argon is of general interest, in particular for the construction of large scale WIMP dark matter searches and detectors…

天体物理仪器与方法 · 物理学 2012-05-03 H. O. Back , F. Calaprice , C. Condon , E. de Haas , R. Ford , C. Galbiati , A. Goretti , T. Hohman , An. Inanni , B. Loer , D. Montanari , A. Nelson , A. Pocar

The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one…

仪器与探测器 · 物理学 2021-12-06 DarkSide Collaboration , P. Agnes , S. Albergo , I. F. M. Albuquerque , T. Alexander , A. Alici , A. K. Alton , P. Amaudruz , M. Arba , P. Arpaia , S. Arcelli , M. Ave , I. Ch. Avetissov , R. I. Avetisov , O. Azzolini , H. O. Back , Z. Balmforth , V. Barbarian , A. Barrado Olmedo , P. Barrillon , A. Basco , G. Batignani , A. Bondar , W. M. Bonivento , E. Borisova , B. Bottino , M. G. Boulay , G. Buccino , S. Bussino , J. Busto , A. Buzulutskov , M. Cadeddu , M. Cadoni , A. Caminata , E. V. Canesi , N. Canci , G. Cappello , M. Caravati , M. C , N. Cargioli , M. Carlini , F. Carnesecchi , P. Castello , A. Castellani , S. Catalanotti , V. Cataudella , P. Cavalcante , S. Cavuoti , S. Cebrian , J. M. Cela Ruiz , B. Celano , S. Chashin , A. Chepurnov , C. Cical , L. Cifarelli , D. Cintas , F. Coccetti , V. Cocco , M. Colocci , E. Conde Vilda , L. Consiglio , S. Copello , J. Corning , G. Covone , P. Czudak , M. D'Aniello , S. D'Auria , M. D. Da Rocha Rolo , O. Dadoun , M. Daniel , S. Davini , A. De Candia , S. De Cecco , A. De Falco , G. De Filippis , D. De Gruttola , G. De Guido , G. De Rosa , M. Della Valle , G. Dellacasa , S. De Pasquale , A. V. Derbin , A. Devoto , L. Di Noto , F. Di Eusanio , C. Dionisi , P. Di Stefano , G. Dolganov , D. Dongiovanni , F. Dordei , M. Downing , T. Erjavec , S. Falciano , S. Farenzena , M. Fernandez Diaz , C. Filip , G. Fiorillo , A. Franceschi , D. Franco , E. Frolov , N. Funicello , F. Gabriele , C. Galbiati , M. Garbini , P. Garcia Abia , A. Gendotti , C. Ghiano , R. A. Giampaolo , C. Giganti , M. A. Giorgi , G. K. Giovanetti , M. L. Gligan , V. Goicoechea Casanueva , A. Gola , A. M. Goretti , R. Graciani Diaz , G. Y. Grigoriev , A. Grobov , M. Gromov , M. Guan , M. Guerzoni , M. Guetti , M. Gulino , C. Guo , B. R. Hackett , A. Hallin , M. Haranczyk , S. Hill , S. Horikawa , F. Hubaut , T. Hugues , E. V. Hungerford , An. Ianni , V. Ippolito , C. C. James , C. Jillings , P. Kachru , A. A. Kemp , C. L. Kendziora , G. Keppel , A. V. Khomyakov , S. Kim , A. Kish , I. Kochanek , K. Kondo , G. Korga , A. Kubankin , R. Kugathasan , M. Kuss , M. Kuźniak , M. La Commara , L. La Delfa , D. La Grasta , M. Lai , N. Lami , S. Langrock , M. Leyton , X. Li , L. Lidey , F. Lippi , M. Lissia , G. Longo , N. Maccioni , I. N. Machulin , L. Mapelli , A. Marasciulli , A. Margotti , S. M. Mari , J. Maricic , M. Marinelli , M. Mart , A. D. Martinez Rojas , A. Martini , C. J. Martoff , M. Mascia , M. Masetto , A. Masoni , A. Mazzi , A. B. McDonald , J. Mclaughlin , A. Messina , P. D. Meyers , T. Miletic , R. Milincic , R. Miola , A. Moggi , A. Moharana , S. Moioli , J. Monroe , S. Morisi , M. Morrocchi , E. N. Mozhevitina , T. Mr , V. N. Muratova , A. Murenu , C. Muscas , L. Musenich , P. Musico , R. Nania , T. Napolitano , A. Navrer Agasson , M. Nessi , I. Nikulin , J. Nowak , A. Oleinik , V. Oleynikov , L. Pagani , M. Pallavicini , S. Palmas , L. Pandola , E. Pantic , E. Paoloni , G. Paternoster , P. A. Pegoraro , L. A. Pellegrini , C. Pellegrino , K. Pelczar , F. Perotti , V. Pesudo , E. Picciau , F. Pietropaolo , T. Pinna , A. Pocar , P. Podda , D. M. Poehlmann , S. Pordes , S. S. Poudel , P. Pralavorio , D. Price , F. Raffaelli , F. Ragusa , A. Ramirez , M. Razeti , A. Razeto , A. L. Renshaw , S. Rescia , M. Rescigno , F. Resnati , F. Retiere , L. P. Rignanese , C. Ripoli , A. Rivetti , J. Rode , L. Romero , M. Rossi , A. Rubbia , M. Rucaj , G. M. Sabiu , P. Salatino , O. Samoylov , E. S , E. Sandford , S. Sanfilippo , V. A. Sangiorgio , V. Santacroce , D. Santone , R. Santorelli , A. Santucci , C. Savarese , E. Scapparone , B. Schlitzer , G. Scioli , D. A. Semenov , B. Shaw , A. Shchagin , A. Sheshukov , M. Simeone , P. Skensved , M. D. Skorokhvatov , O. Smirnov , B. Smith , A. Sokolov , R. Stefanizzi , A. Steri , S. Stracka , V. Strickland , M. Stringer , S. Sulis , Y. Suvorov , A. M. Szelc , J. Z. Zsücs-Balázs , R. Tartaglia , G. Testera , T. N. Thorpe , A. Tonazzo , S. Torres-Lara , S. Tosti , A. Tricomi , M. Tuveri , E. V. Unzhakov , G. Usai , T. Vallivilayil John , S. Vescovi , T. Viant , S. Viel , A. Vishneva , R. B. Vogelaar , M. Wada , H. Wang , Y. Wang , S. Westerdale , R. J. Wheadon , L. Williams , Ma. M. Wojcik , Ma. Wojcik , X. Xiao , C. Yang , A. Zani , F. Zenobio , A. Zichichi , G. Zuzel , M. P. Zykova

We report the first measurement of the flux-integrated cross section of $\nu_{\mu}$ charged-current single $\pi^{0}$ production on argon. This measurement is performed with the MicroBooNE detector, an 85 ton active mass liquid argon time…

高能物理 - 实验 · 物理学 2023-02-18 MicroBooNE collaboration , C. Adams , M. Alrashed , R. An , J. Anthony , J. Asaadi , A. Ashkenazi , M. Auger , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , A. Bhat , K. Bhattacharya , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , I. Caro Terrazas , R. Carr , R. Castillo Fernandez , F. Cavanna , G. Cerati , Y. Chen , E. Church , D. Cianci , E. O. Cohen , G. H. Collin , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , M. Del Tutto , D. Devitt , A. Diaz , K. Duffy , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , J. J. Evans , A. A. Fadeeva , R. S. Fitzpatrick , B. T. Fleming , D. Franco , A. P. Furmanski , D. Garcia-Gamez , V. Genty , D. Goeldi , S. Gollapinni , O. Goodwin , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , P. Guzowski , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , G. A. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , X. Ji , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , Y. -J. Jwa , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , I. Lepetic , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , S. Marcocci , C. Mariani , J. Marshall , J. Martin-Albo , D. A. Martinez Caicedo , A. Mastbaum , V. Meddage , T. Mettler , K. Mistry , A. Mogan , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , M. Murphy , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Pandey , V. Paolone , A. Papadopoulou , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , A. Rafique , L. Ren , L. Rochester , M. Ross-Lonergan , C. Rudolf von Rohr , B. Russell , G. Scanavini , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , K. Sutton , S. Sword-Fehlberg , A. M. Szelc , N. Tagg , W. Tang , K. Terao , M. Thomson , R. T. Thornton , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , H. Wei , D. A. Wickremasinghe , K. Wierman , Z. Williams , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , G. Yarbrough , L. E. Yates , G. P. Zeller , J. Zennamo , C. Zhang

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…

仪器与探测器 · 物理学 2017-06-05 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in…

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector…

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, USA. The ICARUS T600 detector is made of four large Time Projection Chambers,…

高能物理 - 实验 · 物理学 2026-04-13 F. Abd Alrahman , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewicz , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , O. Beltramello , S. Bertolucci , M. Betancourt , A. Blanchet , F. Boffelli , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , J. Bremer , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , M. Chalifour , P. Chambouvet , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chithirasreemadam , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , H. Da Motta , M. Dallolio , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , R. Doubnik , F. Drielsma , J. Dyer , S. Dytman , C. Fabre , A. Falcone , C. Farnese , A. Fava , N. Gallice , F. G. Garcia , C. Gatto , M. Geynisman , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , K. Hassinin , H. Hausner , A. Heggestuen , B. Howard , R. Howell , Z. Hulcher , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , D. Mladenov , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , M. Nessi , T. Nichols , S. Palestini , M. Pallavicini , V. Paolone , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , M. L Pumo , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , E. Richards , M. Rosenberg , M. Rossella , N. Rowe , P. Roy , C. Rubbia , M. Saad , S. Saha , G. Salmoria , S. Samanta , M. Satgia , A. Scaramelli , D. Schmit , F. Schwartz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , K. V. Tsang , S. Tufanli , T. Usher , F. Varanini , N. Vardy , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , F. A. Wieler , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Worcester , M. Wospakrik , S. Yadav , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli , M. Zuckerbrot

Detectors for direct dark matter search using noble gases in liquid phase as detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated cryogenic system has been assembled and operated at the…

仪器与探测器 · 物理学 2023-03-29 G. Grauso , A. Basco , N. Canci , R. de Asmundis , F. Di Capua , G. Matteucci , Y. Suvorov , G. Fiorillo

The ArgoNeuT liquid argon time projection chamber has collected thousands of neutrino and antineutrino events during an extended run period in the NuMI beam-line at Fermilab. This paper focuses on the main aspects of the detector layout and…

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify…

仪器与探测器 · 物理学 2024-05-17 20k Collaboration

The proliferation of liquid argon time projection chamber detectors makes the characterization of the dielectric properties of liquid argon a critical task. To improve understanding of these properties, a systematic study of the breakdown…

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based…

仪器与探测器 · 物理学 2022-06-15 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , A. Bernard , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , S. Farrell , A. D. Ferella , H. Fischer , S. Form , W. Fulgione , P. Gaemers , R. Gaior , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , A. Higuera , C. Hils , K. Hiraide , L. Hoetzsch , J. Howlett , C. Huhmann , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , N. Kato , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , K. Ni , U. Oberlack , J. Palacio , R. Peres , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , J. M. F. dos Santos , G. Sartorelli , J. Schreiner , D. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , Y. Zhang , M. Zhong , T. Zhu , J. P. Zopounidis

A filter system for removing electronegative impurities from liquid argon is described. The active components of the filter are adsorbing molecular sieve and activated-copper-coated alumina granules. The system is capable of purifying…

仪器与探测器 · 物理学 2009-06-25 A. Curioni , B. T. Fleming , W. Jaskierny , C. Kendziora , J. Krider , S. Pordes , M. Soderberg , J. Spitz , T. Tope , T. Wongjirad

LEGEND-200 requires high-purity liquid argon for effective background discrimination. In this paper, we present the design, construction, and performance of a dedicated liquid argon purification system, along with the procurement and…

This work presents single-differential electron-neutrino charged-current cross sections on argon measured using the MicroBooNE detector at the Fermi National Accelerator Laboratory. The analysis uses data recorded when the Neutrinos at the…

高能物理 - 实验 · 物理学 2026-03-06 MicroBooNE collaboration , P. Abratenko , D. Andrade Aldana , L. Arellano , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , A. Barnard , G. Barr , D. Barrow , J. Barrow , V. Basque , J. Bateman , B. Behera , O. Benevides Rodrigues , S. Berkman , A. Bhat , M. Bhattacharya , V. Bhelande , M. Bishai , A. Blake , B. Bogart , T. Bolton , M. B. Brunetti , L. Camilleri , D. Caratelli , F. Cavanna , G. Cerati , A. Chappell , Y. Chen , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , R. Cross , M. Del Tutto , S. R. Dennis , P. Detje , R. Diurba , Z. Djurcic , K. Duffy , S. Dytman , B. Eberly , P. Englezos , A. Ereditato , J. J. Evans , C. Fang , B. T. Fleming , W. Foreman , D. Franco , A. P. Furmanski , F. Gao , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , E. Gramellini , P. Green , H. Greenlee , L. Gu , W. Gu , R. Guenette , K. Gumpula , P. Guzowski , L. Hagaman , M. D. Handley , O. Hen , C. Hilgenberg , G. A. Horton-Smith , A. Hussain , B. Irwin , M. S. Ismail , C. James , X. Ji , J. H. Jo , R. A. Johnson , D. Kalra , G. Karagiorgi , W. Ketchum , M. Kirby , T. Kobilarcik , K. Kumar , N. Lane , J. -Y. Li , Y. Li , K. Lin , B. R. Littlejohn , L. Liu , W. C. Louis , X. Luo , T. Mahmud , N. Majeed , C. Mariani , J. Marshall , N. Martinez , D. A. Martinez Caicedo , S. Martynenko , A. Mastbaum , I. Mawby , N. McConkey , L. Mellet , J. Mendez , J. Micallef , K. Miller , T. Mohayai , A. Mogan , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , M. M. Moudgalya , S. Mulleria Babu , D. Naples , A. Navrer-Agasson , N. Nayak , M. Nebot-Guinot , C. Nguyen , J. Nowak , N. Oza , O. Palamara , N. Pallat , V. Paolone , A. Papadopoulou , V. Papavassiliou , H. Parkinson , S. F. Pate , N. Patel , Z. Pavlovic , E. Piasetzky , K. Pletcher , I. Pophale , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , I. Safa , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , E. L. Snider , S. Soldner-Rembold , J. Spitz , M. Stancari , J. St. John , T. Strauss , A. M. Szelc , N. Taniuchi , K. Terao , C. Thorpe , D. Torbunov , D. Totani , M. Toups , A. Trettin , Y. -T. Tsai , J. Tyler , M. A. Uchida , T. Usher , B. Viren , J. Wang , M. Weber , H. Wei , A. J. White , S. Wolbers , T. Wongjirad , K. Wresilo , W. Wu , E. Yandel , T. Yang , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

仪器与探测器 · 物理学 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…

The prevalent use of large volume liquid argon detectors strongly motivates the development of novel readout and monitoring technology which functions at cryogenic temperatures. This paper presents the development of a cryogenic CMOS camera…

仪器与探测器 · 物理学 2017-04-05 Nicola McConkey , Neil Spooner , Matthew Thiesse , Michael Wallbank , Thomas Karl Warburton