相关论文: High count rate {\gamma}-ray spectroscopy with LaB…
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in…
A simplified digital spectrometer for the study of $\gamma$-rays with energies up to $\sim100$ MeV is presented and tested. The spectrometer is only consisted of a fast digital oscilloscope and three scintillation detectors which can work…
The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…
A prototype of LaBr3:Ce in situ gamma-ray spectrometer for marine environmental monitoring is developed and applied for in situ measurement. A 3-inch LaBr3:Ce scintillator is used in the detector, and a digital pulse process electronics is…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the…
Scintillation properties of the new Tl2LaCl5: xCe3+ where x = 0, 0.5, 1 and 10 mole % (TLC: Ce3+) single crystals are presented. Two zones vertical Bridgman technique is used for the growth of this scintillation material. High Z-number (79)…
We have characterized in depth the time response of three detectors equipped with cylindrical LaBr$_{3}$ (Ce) crystals with dimensions of 1-in. in height and 1-in. in diameter, and having nominal Ce doping concentration of 5%, 8% and 10%.…
The nonproportional scintillation response of LaBr3 doped with 5% Ce3+ and of LaCl3 doped with 10% Ce3+ was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely…
An underwater in situ gamma ray spectrometer based on LaBr3 was developed and optimized to monitor marine radioactivity. The intrinsic background mainly from La138 and Ac227 of LaBr3 was well determined by low background measurement and…
Here we report on the characterization of one of the large-volume LaBr$_{3}$:Ce detectors for the ELIGANT project at ELI-NP. The main focus of this work is the response function for high-energy $\gamma$ rays of such detectors. In…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC)…
Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming…
A sensitive laser spectroscopic method has been applied to the quantitative determination of the isotope ratio of helium at the level of 3He/4He = 10^-7 - 10^-5. The resonant absorption of 1083 nm laser light by the metastable 3He atoms in…
A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed x-ray sources has been developed. It allows the direct use of x-ray spectroscopy without artificially decreasing the number of counts in the…
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV…
A model-independent method is proposed to characterize and correct charge sharing spectral distortions in energy-resolved X-ray acquisitions with pixellated photon-counting detectors. The technique is based on the determination of a…
Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…
Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of…