中文
相关论文

相关论文: Stability Transfer between Two Clock Lasers Operat…

200 篇论文

The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…

We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…

We report the absolute frequency measurement of the 5s2 1S0-5s5p 3P0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center (NTSC). Its systematic frequency shifts are evaluated carefully with a total relative…

原子物理 · 物理学 2023-02-01 Xiaotong Lu , Feng Guo , Yebing Wang , Qinfang Xu , Chihua Zhou , Jingjing Xia , Wenjun Wu , Hong Chang

We perform spectroscopic observations of the 698-nm clock transition in $^{87}$Sr confined in an optical lattice using a laser linewidth transfer technique. A narrow-linewidth laser interrogating the clock transition is prepared by…

With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic…

We describe a frequency stabilized diode laser at 698 nm used for high resolution spectroscopy of the 1S0-3P0 strontium clock transition. For the laser stabilization we use state-of-the-art symmetrically suspended optical cavities optimized…

原子物理 · 物理学 2011-01-13 Marco. G. Tarallo , Nicola Poli , Marco Schioppo , Guglielmo M. Tino

We demonstrate a precision frequency measurement using a phase-stabilized 120-km optical fiber link over a physical distance of 50 km. The transition frequency of the 87Sr optical lattice clock at the University of Tokyo is measured to be…

We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the…

Aided by ultra-high resolution spectroscopy, the overall systematic uncertainty of the $^{1}S_{0}$-$^{3}P_{0}$ clock resonance for lattice-confined $^{87}$Sr has been characterized to $9\times10^{-16}$. This uncertainty is at a level…

We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is…

With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help…

The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the…

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been…

We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 {\mu}m to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 -…

光学 · 物理学 2015-11-30 C. Hagemann , C. Grebing , T. Kessler , St. Falke , C. Lisdat , H. Schnatz , F. Riehle , U. Sterr

Optical frequency comparison of the 40Ca+ clock transition \nu_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition \nu_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio \nu_{Ca} / \nu_{Sr} = 0.957 631 202 358…

We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the…

The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the…

The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record…

The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser…

原子物理 · 物理学 2015-10-28 Hidekazu Hachisu , Tetsuya Ido

We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain…

‹ 上一页 1 2 3 10 下一页 ›