相关论文: Comparison of the current LHC Collimators and the …
The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) will double its beam intensity for the needs of High Energy Physics frontier. In order to ensure coherent stability until the beams are put in collision, the transverse…
As part of an upgrade to the LHC collimation system, 8 TCTP and 1 TCSG collimators are proposed to replace existing collimators in the collimation system. In an effort to review all equipment placed in the accelerator complex for potential…
The LHC collimators have very complicated mechanical designs including movable jaws made of higly resistive materials, ferrite materials, tiny RF contacts. Since the jaws are moved very close to the circulating beams their contribution in…
While well studied in the absence of beam-beam and while colliding head-on, the stability of the LHC beams can be very critical in intermediate steps. During the squeeze, the long-range beam-beam interaction becomes a critical component of…
The importance of collimator R&D with test beam facilities is demonstrated with the example of ILC collimator studies at SLAC End Station A. Related LHC collimator aspects and longer term plans are addressed.
Interest in highly-compressed electron beams has been increasing in recent times, driven by the study of non-linear and even non-perturbative aspects of QED [2]. The FACET-II [7] facility at SLAC is currently (at the time of writing) being…
The Large Hadron Collider (LHC) uses a multi-stage collimator system to absorb the growing halo of circulating beams to protect and ensure reliable operation of superconducting magnets. A similar system is planned for the Future Circular…
Which gain and phase have to be set for a bunch-by-bunch transverse damper, and at which chromaticity it is better to stay? These questions are considered for three models: the two-particle model with possible quadrupole wake, the author's…
In accelerator projects involving the use of very short bunches, such as the Linac Coherent Light Source (LCLS)-where the rms bunch length in the undulator section is 30 micron-, it appears that even submicron imperfections in the beam tube…
Collimation systems in particle accelerators are designed to safely and efficiently dispose of unavoidable beam losses during operation. Their specific roles vary depending on the type of accelerator. The state of the art in hadron beam…
The Large Hadron Electron Collider (LHeC) is a proposed upgrade to the LHC, to provide high energy, high luminosity electron-proton collisions to run concurrently with Phase 2 of the LHC. The baseline design of a detector for the LHeC is…
High frequency High Order Modes can significantly affect the coupled-bunch stability in a circular accelerator. With a large enough shunt impedance they may drive a coupled-bunch transverse instability. We have developed an analytical model…
Collimation systems in particle accelerators are designed to dispose of unavoidable losses safely and efficiently during beam operation. Different roles are required for different types of accelerator. The present state of the art in beam…
Collimation systems are essential in particle accelerators to safely and efficiently manage unavoidable beam losses during operation. These systems rely on collimators, which are specially designed movable jaws or absorbers positioned close…
The robustness of a structured collimation device is discussed for an intense-laser-produced ion beam. In this paper the ion beam collimation is realized by the solid structured collimation device, which produces the transverse electric…
The FCC-ee impedance model is being constantly updated closely following the vacuum chamber design and parameters evolution. In particular, at present, a thicker NEG coating of 150 nm (instead of previous 100 nm) has been suggested by the…
Chapter 5 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in…
The Large Hadron Electron Collider (LHeC) is a proposed upgrade to the LHC, to provide high energy, high luminosity electron-proton and electron-ion collisions to run concurrently with Phase 2 of the LHC. The key elements of the LHeC…
The wire method is a more rapid and less costly method to measure impedances of RF components compared to methods using a beam. A setup using a single displaced wire to excite and measure transverse resonant modes in accelerating structures…
Chapter 11 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in…