中文
相关论文

相关论文: A time-resolution study with a plastic scintillato…

200 篇论文

Multi-pixel photodiodes operating in a limited Geiger mode will be used for photoreadout of scintillator counters in underground cosmic ray experiment EMMA. Main parameters of photodiodes and the performance of EMMA scintillator counters…

We give an analytic treatment of the time resolution and efficiency of Single Photon Avalanche Diodes (SPADs) and Silicon Photomultipliers (SiPMs). We provide closed-form expressions for structures with uniform electric fields and efficient…

仪器与探测器 · 物理学 2021-05-05 Werner Riegler , Philipp Windischhofer

A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta…

仪器与探测器 · 物理学 2015-05-28 I. Kreslo , I. Badhrees , S. Delaquis , A. Ereditato , S. Janos , M. Messina , U. Moser , B. Rossi , M. Zeller

The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…

医学物理 · 物理学 2008-05-06 N. D'Ascenzo , E. Garutti , M. Goettlich , H. C. Schultz-Coulon , A. Tadday

Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…

仪器与探测器 · 物理学 2024-01-18 Varlen Grabski

The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…

The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…

仪器与探测器 · 物理学 2019-08-13 Christian Soldner

A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…

仪器与探测器 · 物理学 2016-03-10 Er-Lei Chen , Chang-Qing Feng , Chun-Feng Ye , Shu-Bin Liu , Dong-Dong Jin , Jian Lian , Hui-Jun Hu

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a…

Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon…

仪器与探测器 · 物理学 2016-04-15 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…

仪器与探测器 · 物理学 2015-12-09 G. Belli , M. Gabusi , G. Musitelli , R. Nardò , S. P. Ratti , A. Tamborini , P. Vitulo

The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…

First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…

仪器与探测器 · 物理学 2015-06-26 V. N. Solovov , A. Hitachi , V. Chepel , M. I. Lopes , R. Ferreira Marques , A. J. P. L. Policarpo

The light yield and the time resolution of different types of 3 m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9…

We derive expressions for the time resolution of silicon detectors, using the Landau theory and a PAI model for describing the charge deposit of high energy particles. First we use the centroid time of the induced signal and derive analytic…

仪器与探测器 · 物理学 2019-06-27 Werner Riegler , Gianluca Aglieri Rinella

Synchrotron radiation light sources produce intense beam of X-ray with ultra-short pulse and nanosecond period. This of-fers the opportunities for the time resolution experiments. Achieving higher counting rate and faster arriving time is…

仪器与探测器 · 物理学 2015-11-05 Zhen-jie Li , Qiu-ju Li , Peng Liu , Shan-feng Wang , Wei-wei Dong , Yang-fan Zhou